UL 1610 & UL 365 GRADE A CENTRAL STATION & POLICE
STATION MERCANTILE BURGLARY INSTALLATIONS USING HIGH
LINE SECURITY DIRECT WIRE TRANSMISSION
IMPORTANT!: Requires the use of No. 4140ATX Control.
BELL CONNECTIONS Audible alarms must be provided by the use of AB12 Bell in Box..The AB12
must be mounted so that lt can be heard outside the protected area.
INSTALLATION NOTES 1.
2.
3.
-4.
5.
6.
7.
6.
All wiring between ABlP and 4140ATX must be in conduit, and all
conduit holes (knockouts) on the Control panel shall be used or blocked
tram acoess. (See Diagram 36.)
Use 12V 4 AH (minimum) Battery.
Value of End-of-line resistor is 1K ohms (‘41~0).
Bntry Delays-cannot exceed 60 seconds for UL Commercial Burglary
tjistings.
~eltir$out cannot be less than 16 minutes for UL Commercial Burglary
If 419OWH Dual Point RPMs are used, tamper detection in Field Address
‘24 must be enabled (enter 0).
Field ‘16 Confirmation of Arming Ding must be enabled.
Field ‘16 AC Loss Alarm after 4 hours must be enabled.
LOCATE
k+l oRzL
687.888.346 -_by
WITHIN
414OATX
CABINET
6M
I I
I I
NOT I I
-
N.O. CONTACTS (IF USED)
CLOSING ACROSS THESE
TERMINALS RESULTS
IN A TELEPHONE LINE
TROUBLE CONDITION.
TELEPHONE LINE TO MINIMODULARM
OR MODULARM TYPE SYSTEM.
OUTPUT RATING: 3 TO 20 VAC
(UP TO 5mA MAX).
Diagram 43. GRADE A CENTRAL STATION INSTALLATION USING 346 REVERSING RELAY MODULE
414OAlX CABINET)
SEE No. 346’S
INSTAUATION
INSTRUCTIONS
FOR ADD’L
INFO.
ADEMCO’s VISTA XM SERIES TECHNICAL REFERENCE MANUAL
WWW.DIYALARMFORUM.COM