SECTION XIII 105
SECTION XIII
SPECIAL UL REQUIREMENTS
PRODUCTS NOT UL LISTED
l
675 Ground Start Module
9 4148 Keyswitch
l
4133 Rough-In Ring
9 4136 cover for No. 4133 Rough-In Ring
l
4145 Splice Box Kii
l
4149 702 Siren Junction Box Kit
l
ABB1031 Motor Bell and Box
l
702 Outdoor Siren
l
4134-12 Metal Cabinet
. 4132LG Battery Backbox for 4AH battery
UL 609 GRADE A LOCAL MERCANTILE BURGLARY INSTALLATIONS
IMPORTANT!: Requires the use of NO. 414OATX Control.
BELL CONNECTIONS
Audible alarms must be provided by the use of AB12 Bell in Box..The AB12
must be mounted so that it canbe heard outside the protected area.
INSTALLATION NOTES
1. All wiring between AB12 and 4140ATX must be in conduit, and all
conduit holes (knockouts) on the Control panel shall be used or blocked
from access.
2. Use 12V 4 AH (minimum) Battery.
3. Value of End&line resistor is 1K ohms (‘41~0).
4. Entry Delays cannot exceed 60 seconds for UL Commercial Burglary
Listings.
5. Bell timeout cannot be less than 16 minutes for UL Commercial Burglary
Listings.
6. If 4190WH Dual Point RPMs are used, tamper detection in Field Address
‘24 must be enabled (enter 0).
7. Field ‘16 Confirmation of Arming Ding must be enabled.
8. Field l 18 AC Loss Alamo after 4 hours must be enabled.
9. Field ‘27 24 Hour Test must be enabled.
10. Ademw WAll2-1 Tamper Switch must be used to supervise cover.
11. Field 23 Muiliole Alarms must be enabled.
EARTH GROUND
FAl WOUL
Diagram 38. No. 414oATX UL GRADE A INSTALLATION
WIRING:
BELL CONNECTIONS:
12. Field 28 Power up in previous state must be enabled.
i
ALL WIRING
INNER CABINET
IN CONDUIT
SEENOTE 1
--__-__----_-_-_-------------.
ABV BELL IN BOX :
I
I
I
I
WWW.DIYALARMFORUM.COM