TROUBLESHOOTING
- D. WIRELESS -
“88” or “90” appears
in console display
and rapid beeping
occurs
l
The receiver is not receiving any signals from any of the transmitters in
the system. .An “68. is for the 2nd 4280; a “90’ is for the 1 st 4280. These
displays are enabled by assigning a zone response type in program fields
1’06, and 1’09. The recommended response is either zone type 05 or
07 (see
the
ZONE TYPE DEFlNlTlONS section. wireless installation.
l
Check that the antenna is installed properly and is not shorted to any
metal object, refer to WIRELESS EXPANSION section for details.
. Check that the transmitters are powered up with fresh 9 voit batteries.
l
Check that the house ID’s match between transmitters and the 4260.
l
Determine if anything is blocking transmission to the 4280 (ex: metal
cabinets or shetves, etc.)
l
Remove the 4280% cover and put the system in the test mode, then see
if the transmitters check-in. If not, move the 4260 to another location and
test again.
“89”
or “9,”
appears in console
display and rapid
beeping occurs
l
The 4280 is not responding to the Control panel. An ‘89’ refers to the
second 4280 and a 91’ refers to the first 4280.
l
Check that the 4280’s cover is on and the magnet is in close proximity to
the reed switch.
. Check that the polling bop is attached to the 4280.
l
Determine that the total current draw on the polling loop is not more than
64mA. See SPECIFICATIONS. If the draw does exceed 64mA, install a
..-.
4197 loop extender module as described in the WIRELESS
EXPANSION section, or power the 4280 from auxiliary power, as
described.
l
Check that the polling loop length is in agreement with the
recommended wire gauge. If the length exceeds what is recommended,
install a 4197 loop extender module as described in the WIRELESS
EXPANSION section.
Zones, not pro-
* Check program fields l 02 through ‘05, and 1’01 through 1’05’to make
grammed in the
sure .all unused zones are 00s.
system, are indicating
l
Check program fields 1’18 through 1’25 to make sure that all non-RF
“CHECK” conditions
zones are 0s.
Zones indicating
“NOT READY” condition,
l
Put the system in the SNIFFER MODE for at least 2 hours. to see if
but transmitter contact
another system in the area is using the same house ID. If so, change this
loop is intact
system’s house ID number at the 4280 and at all transmitters.
l
Make sure zones In question are selected as RF in fields 1’18-1’25.
.-.
ADEMCO’s
VISTA
XM SERIES TECHNICAL REFERENCE MANUAL
WWW.DIYALARMFORUM.COM