POWERZNG THE SYSTEM
,--.
POWER CONNECTIONS
The
Power Pack should be located as close as possible to the Control to
prevent voltage drops to the Control. A proper earth ground must be
provided for the system in order to protect the system from lightning and
electrostatii
dirge damage. TB2
terminal 3 is the earth ground
connection point for the 4140XM, and the white flying lead is the earth
ground lead fix the 4130XhU5130XM Controls.
Connect a lead from this
terminal (or white lead) to a proper earth ground. Be sure the vottage trigger
outputs and Dir board are also connected to a proper earth ground.
Connect the Power Pack and battery to the Control as shown:
TB2
T02
\
I
QOOOJ
3 4 s 6
I
EARTH
GROUND
- (+I
18 MC
wi6a
DC POWER
(+I
f-1
@BsomA
PACK
t-1
12 VOLT
STANDBY
GEL CELL BAnERY
b
wAl4 mqulfd for
CAlJTlOw: ‘OBSERVE FOLARIlV!
UL imtallations)
‘KEEP WIRE RUNS AS SHORT AS POSSIBLE!
‘4eOAH MINIMUM BAmERY CAPACITY
‘B.OAll MAXIMUM BATTERY CAPACllY
Diagmm 37A. 4140XM POWER PACK BAmRY CONNECTIONS
VISTA
CONTROL
STANDBY
BAmERY
S.&H MAXIMUM!
CALmoM 0BBERvEPolARm
KEEP WIRE RUNS AS SHORT AS POSSIBLE1
Dirgmm 37B.M30XM/4130XY P&l% PACK AND BATTERY CONNECTIONS
/--=.