SYSTEM CONFXCVRATXON (ZONES)
USING TWO
RECEIVERS TO
For installations where the area to be protected goes well beyond the 200
range of the system, or the building configuration preventsgetting the rated
INCREASE COVERAGE
range in ail paths to transmitters, a second receiver can be installed. The first
4280 is bcated at one end of the premises and the second 4280 at the other
with both 4280s connected to the same P-wire polling loop.
AREA 12
Dlsgmm 12. TWO WIRELESS RECEIVERS TO INCREASE COVERAGE
ADVISORIES
1. if dual 4280s or 4280-8s are used:
A. Both must be at least 10 feet from each other, as well as from the
,-.
vista XM Control panel and remote consoles.
B. One of the 4280s or 4286-8s must be powered from Aux. power
(see SPECIFICATIONS).
C. The house IDS must be the same.
0. Using two Receivers &es not increase the number of transmitters
the system can support (62 transmitters, plus a wireless keypad).
2. Follow the chart below for max. polling loop runs:
V22 gauge @65fY max
320 gauge @95V max
‘#I8 gauge @lSOO’ max
‘#16 gauge @ 2400’ max
Note: Twisted pair recommended for ail normal runs.
IMPORTANT: The maximum combined polling loop run is 4000’. If using
shielded wire, the maximum is 2000’.
CAUTION:
if an intercom system is being used, the polling loop wires must
be as far from the intercom wiring as possible (minimum 6’). if this spacing
cannot be accomplished. shielded wire must be used. If this is not done,
interference on the intercom system might occur! Also note that the
maximum total wire supported is cut in hall when shielded wire is used.