SECTION
XIV 113
SYMPTOM
Console is
inoperable;
erratic display
SECTION XIV
TROUBLESHOOTING
- A. CONSOLES -
.
Power down completely (AC + battery), disconnect the battery, and
power up again (AC only).
l
Check that auxiliary voltage is between 13SVDC-14.OVDC. If not,
disconnect all auxiliary devices, and take another reading. If within the
above range, there is too much current being drawn by the auxiliary
devices. (see the SPECIFICATIONS section tar the current draw of each
device). lf still not within the above range, check incoming power from the
No. 1350 (or 1360) power pack. Voltage should bs between 16-22VDC
with the control hooked up, and 20-24VDC with no load. If below 16VDC,
carefully check the AC supply for a minimum of 110 VAC.
l
With all auxiliary devices and battery still disconnected, check the voltage
on the red & black battery leads. It should be 13.65VDC (approx.). lf not,
replace the Control. If it is @ 13.65VDC. the battery may not be at full
charge (allow the battery to charge 4-6 hours before reconnecting the
auxiliary devices) or the battery may be bad, and not able to hold a
charge.
Console displays
“Not Ready” but
no zone is
displayed when
the I’] ready key
is depressed
l
Check to make sure there is a zone type response entered in program
lield ‘05 for ‘97 (polling loop short). lf no zone response is entered and
a loop short occurs, the display will only read ‘NOT READY”, without an
explanation.
l
Check to detemrine lf a right loop has been enabled for an RPM in a zone
expanded system and no zone response is assigned to that sensor loop.