VISTA-128FBP/VISTA-250FBP Installation and Setup Guide
6-8
1. Enter the schedule number (01-20) and time
window number (01-20), and note the day of the
week the action is desired.
2. Enter the code for the desired action and
action specifier. The action codes represent the
events that are to take place when the scheduled
time is reached. Each action also requires an
action specifier, which defines what the action will
affect (relay, relay group, partition, zone list, user
group). The action specifier varies, depending on
the type of action selected.
The following is a list of the Action Codes (desired
actions) used when programming Time-Driven events.
Note that these codes are independent of the relay
codes programmed during Output Programming in the
#93 Menu Mode.
Relay Commands
Action Code Action Action Specifier
01 Relay On Relay #
02 Relay Off Relay #
03 Relay Close for 2 seconds Relay #
04
Relay Close XX minutes (set
in field 1*74)
Relay #
05
Relay Close YY seconds (set
in field 1*75)
Relay #
06 Relay Group On Relay Group #
07 Relay Group Off Relay Group #
08
Relay Group Close for 2
seconds
Relay Group #
09
Relay Group Close XX
minutes (set in field 1*74)
Relay Group #
10
Relay Group Close YY
seconds (set in field 1*75)
Relay Group #
Arm/Disarm Commands
Action Code Action Action Specifier
20 Arm-STAY Partition(s)
21 Arm AWAY Partition(s)
22 Disarm Partition(s)
23
Force Arm STAY (Auto-
bypass faulted zns)
Partition(s)
24
Force Arm AWAY (Auto-
bypass faulted zns)
Partition(s)
25 Arm INSTANT Partition(s)
26 Arm MAXIMUM Partition(s)
The auto-arm warning (field 2*06) applies
when using Time-Driven events to auto-arm.
Temporary schedules do not override an
auto-arming or auto-disarming programmed
in Time-Driven events.
The auto-armin
g
window cannot be extended
using the Installer Code + #82 Mode.
Bypass Commands
Action Code Action Action Specifier
30 Auto bypass Zone list Zone list #
31 Auto unbypass Zone list Zone list #
Open/Close Windows
Action Code Action Action Specifier
40
Enable Opening Window by
partition
Partition(s)
41
Enable Closing Window by
partition
Partition(s)
42
Enable Access Window for
access group
Access Group
50
Off-Normal Reminder
(starts local keypad beeping if
fire or system trouble
condition exists)
None
Access Control Commands 55-78 Not Used
3. Enter the desired activation time (when the
action is to take place). Select from:
Activation
Time
Description
1 Beginning of time window.
2 End of time window.
3
During time window active period only (on at
beginning of window, off at end).
For example, if bypass is selected to activate during
the window, zones in a zone list are bypassed at the
beginning of the window and unbypassed at the end
of the window.
4
Beginning and end of time window (e.g., a coffee
break buzzer). In this example, if relay pulse is
selected, the relay pulses for 2 seconds at the
beginning of the window, signaling the beginning of
the coffee break. At the end of the window it pulses
again, signaling the end of coffee break.
5
Random time at the start of the time window (occurs
within 30 minutes after the start of the time window).
NOTE: Since the randomization for choice 5
occurs within 30 minutes after the start of the
window, the time window duration must be at least
30 minutes.
6
Random time at the end of the time window (occurs
within 30 minutes after the end of the time window).
7
Random during the time window (begins within 30
minutes after the start of the time window and ends
within 30 minutes after the end of the time window).
NOTE: Since the randomization for choice 7
occurs within 30 minutes after the start of the
window, the time window duration must be at least
30 minutes.