VISTA-128FBP/VISTA-250FBP Installation and Setup Guide
5-8
FIELD TITLE and DATA ENTRIES EXPLANATION
1*13
System Sensor Reversing Relay
0 =use neither Zone 1 or Zone 2 inputs
1=use Zone 1 input;
2=use Zone 2 input;
3=use Zone 1 and Zone 2 inputs.
Selects zones for system sensor reversing relay.
Not Used.
1*15
Cancel Verify
0 = disable
1 = enable alarm output pulse upon kissoff of
Cancel report.
NOTE: Field 152 must be enabled to send a Cancel report to the central
station.
1*17
Lobby Partition
0 = none; 1-8 = partition number
Select the Common Lobby Partition.
1*18
Affects Lobby (partition-specific)
0 = disable
1 = enable
If enabled, causes lobby partition to disarm when this partition disarms.
NOTE: This partition must be armed before lobby can be armed.
1*19
Arms Lobby (partition-specific)
0 = disable
1 = enable
If enabled, arming this partition causes the system to attempt to arm the lobby
partition. Field, field 1*18 must also be enabled (partition-specific).
NOTES:
The lobby cannot be armed unless all partitions programmed for affect (field
1*18) is already armed.
If this field is enabled, Field 1*18 for this partition must also be enabled.
Exit Error Logic Enable
0 = disable
1 = enable
If enabled, the system at the end of exit delay, if an entry door or an interior
zone is left open, starts the entry delay period, and activates the Notification
Appliance Circuit(s) and keypad sounders for the duration of entry delay. This
gives the user time to re-enter the premises and disarm the system before exit
error occurs.
If the user does not re-enter the premises and disarm the system, the system
bypasses the faulted entry/exit and/or interior zone(s). The rest of the system
is armed. Also, the following dialer reports are sent to the central station if
programmed:
Exit Error by User (not sent when is using ADEMCO High Speed format);
Entry/Exit or Interior Alarm with the zone number; Bypass reports.
NOTE: This field must be enabled for SIA installations
UL
Exit Error Logic is not suitable for use in a UL installation (must be 0).
1*20
Exit Delay Reset
0 = disable
1 = enable
If enabled, when the panel is armed, the normal exit delay begins. After the
user exits, closes the door and then re-enters the premises, the exit delay
time is reset to the programmed value.
NOTES:
Exit Delay Reset is designed to allow an operator to re-enter the premises to
retrieve a forgotten item without triggering an alarm.
This feature may only be activated once after arming. The Exit Delay must be
enabled for SIA installations.
UL
Exit Delay Reset is not suitable for use in a UL installation (must be 0).
1*21
Cross-Zoning
UL
Cross Zoning is not suitable for use in a UL installation.
Cross Zoning is designed so that a combination of two zones must be faulted within a 5-minute period of each other to cause
an alarm on either zone. This prevents momentary faults from one of the zones from causing an alarm condition. You can
select four "sets" of cross-zones (programmed in data fields 1*22, 1*23, 1*24, and 1*25), keeping in mind the following:
Both zones in each set must protect the same area.
Both zones in each set must be in the same partition.