VISTA-128FBP/VISTA-250FBP Installation and Setup Guide
3-16
Compatible Polling Loop Devices
Model Number Type
4297 Extender Module
4208SN 8 Zone V-Plex Interface
4208SNF 8 Zone V-Plex Class A Interface
269SN V-Plex Holdup Switch
5192SD Photoelectric Smoke Detector Devices
5192SDT Photoelectric Smoke Detector w/Heat Detector
5193SD Photoelectric Smoke Detector Device
5193SDT Photoelectric Smoke Detector w/Heat Detector
4101SN Serial Number Single-Output Relay Module
4208U Universal 8-Zone Expander
4959SN Aluminum Overhead Door Contact
4193SN Serialized 2-Zone Expander
4293SN Serialized 1-Zone Expander
4190SN Serialized 2-Zone Expander
4190WH DIP Switch 2-Zone Expander
998MX Serialized PIR
Quest 2260SN Serialized PIR
IS2500SN V-Plex PIR
V-Plex VSI V-plex Short Isolator
NOTE: If using the new 5193SD/SDT V-Plex smoke detectors (or older 5192SD/SDT with the maintenance DIP sw enabled)
the "Smart" option must be selected in zone programming or when they
enroll unpredictable results may occur if the
smoke goes into a High Sens or Low Sens condition.
To install polling loop devices, perform the following steps:
Step Action
1 Select devices from the list of compatible devices shown previously.
2 Set the DIP switches in the device (if required). Refer to the device’s instructions for the DIP Switch Tables.
3 Mount each device in the desired location. Refer to the device’s instructions.
Run wires from the control panel to each device on the polling loop (see Figure 3-15). No individual wire run
may exceed the lengths shown in the following table.
Maximum Polling Loop Wire Runs
Wire Gauge Max. Length
#22 gauge 650 feet
#20 gauge 950 feet
#18 gauge 1500 feet
#16 gauge 2400 feet
4
5 Wire each device to the polling loop, making sure of the correct polarity (refer to the device’s instructions).
NOTE: If you are using serial number devices, and intend to enroll each device through the keypad
automatically, wire no more than 25 of these devices to the control at a time. Then power up and
program them before connecting the next 25. Leave previously enrolled devices connected.
If you intend to manually enter the serial numbers through the keypad or through Compass downloading
software, all the devices may be connected before powering up to program.