DIRECT WIRE DOWNLOADING
Direct Wire Downloading
Connections
The 4140XMPT2 can be downloaded without using a modem or telephone line
by using V-LINK Downloading Software and a 4100SM Serial Module. The direct
wire downloading connection is to be temporary, and is not part of the permanent
installation. Direct wire downloading is meant as a tool for the installer during the
installation process.
IMPORTANT: The connections between the 4140XMPT2 and the
4100SM are different than those shown in the 4100SM Installation
Instructions. See diagram below for correct connections. In addition, when the
"green" wire is referred to in step 2 of the IN CASE OF DIFFICULTY section of the
4100SM Instructions, use the "violet" wire.
Connector J8, located above connector J7 on the right hand side of the main PC
board, is intended to be interfaced to either a local serial printer (see EVENT
LOGGING CONNECTIONS) or a computer. Make connections to a computer as
shown below. Note that the violet wire connection for a computer
differs from that used when connecting a serial printer.
123456789
NU
J8 CONNECTOR
VIOLET
GRAY
YELLOW
RED
GREEN
BROWN
BLUE
BLACK
IN 2
GROUND
IN 3
GROUND
OUT 5
OUT 6
GROUND
GROUND
PRINTER DTR
4142TR CABLE (SUPPLIED WITH 4100SM)
8
7
6
5
4
3
2
1
4100SM SERIAL MODULE
+ PWR
- (GND)
RXD
not used
not used
TXD
not used
not used
RED BLUE WHITE
To TB6 Aux. Power (+)
(25mA current draw)
To TB7 Aux. Power (-)