DATA FIELD DESCRIPTIONS
Refer to the programming
form provided at the center
of this manual while
reviewing the following
programming sections.
The following section arranges the global (system wide) program fields into the
following functional groups: • Control Options • Wireless Options
• Downloading Options • Partitioning Options
• Dialer Options • Event Logging Options
Note that zone response types can be programmed in fields *02-*05 & 1*01-1*09,
but it is recommended that they be programmed via the #93 Menu Mode. For this
reason, these fields are not discussed in this section.
Control Options *00 Installer Code
4-digit code reserved for installation company use, but can be used by the
customer if needed. This is the only code that can be used to enter the
Program mode from the console. This code cannot be used to disarm the
system if not used to arm, or if Quick Arm was used to arm system. This
code cannot reenter programming mode if exited by the *98 command.
* 1 4 Zone 9 Fast/Slow Response
Enter 1 to set fast response mode (10msec) for appropriate devices wired
to zone 9. Enter 0 for normal response, 350msec. Must be 0 for UL.
* 1 5 Keyswitch Assignment
Enter the partition number 1-8 in which the keyswitch is being used;
otherwise, enter 0. Requires the use of zone 7 wired loop (zone 7 no
longer available as protection zone when used for keyswitch operation). If
the keyswitch is used, the fire and panic alarm voltage triggers automatically
become ARMING and READY status outputs for support of the Keyswitch
LEDs. NOTE: Zone type 10 is automatically assigned to zone 7 if a
keyswitch is used. Reports openings/closing by user "0" if reporting is
enabled in field *40.
* 1 7 AC Power Loss Console Sounding
Entering 1 enables sounding at the console (rapid beeping) when AC power
is lost is desired. Enter 0 if no AC power loss console sounding is desired.
* 1 8 AC Power Loss External Alarm
Entering 1 enables the external alarm sound after AC power has been out
for 4 hours; otherwise enter 0 (no alarm).
* 1 9 Randomize AC Loss Report
Enter 1 to randomize AC loss reporting between 10-40 min. after an actual
AC loss. Enter 0 for normal AC loss reporting (about 2 minutes after actual
AC loss). Selecting this option helps prevent an overload of AC loss
messages at the central station during a community blackout.
* 2 0 Phone Module Phone Access Code
If a 4285 Phone Module is being used, enter the 2-digit phone code used
to access the system. Enter 01-09 for the first digit, and enter 11 (for *) or
12 (for #) for second digit. To disable the phone module, enter 00 for the
first digit and enter 11 for the second digit of the code.
* 2 1 Disable Fire Time-Out
Enter 1 to disable (no timeout) the alarm sounder duration for any zone
designated as a fire zone, regardless of partition, so that fire sounding
continues until the system is reset. Enter 0 if the normal burglary alarm
sounder duration (partition-specific field *13) should apply to fire alarms.
* 2 4 Expansion Zone Tamper Disable
Only applicable if No. 4190WH RPMs are used on the polling loop or 5800
series transmitters are used. This option is used to disable this module's
tamper detection. Enter 1 to disable. Enter 0 if tamper detection is desired.
* 2 5 Burg. Trigger For Response Type 8
This field allows optional triggering of the voltage output on pin 7 of the J7
header for zone response type 8 (24hr. auxiliary). The 0 disable selection is
useful if J7 header pin 7 is used for a panic trigger, and non-panic devices
are used for all zones assigned to zone response type 8 (e.g. water sensor,
temp. sensor). If disabled, only burglary or audible panic alarms will trigger
pin 7. Otherwise, enter 1.