EXAMPLES OF USES FOR RELAYS
The following table lists examples of some possible uses for relays. Refer to the Relay Programming
section of the PROGRAMMING GUIDE for detailed information.
LIST OF START
AND
STOP
CHOICES
A = Action 0=No Response; 1=Close for 2 seconds; 2=Close and stay closed; 3=Pulse on and off
EV = Event 0=Not used; 1=Alarm; 2=fault; 3=Trouble; 4=Restore
ZL = ZONE List 1 to 8 (from Field *81) or 0=Not Used. Upon restore of all zones on RESTORE of ZONE
LIST, relay action will STOP. It need not be same list as used for START
ZT = Zone Type/System Operation
Choices For Zone Types Are:
00 = No Response 06 = 24 Hr Silent
01 = Entry/Exit 07 = 24 Hr Audible
03 = Perimeter 08 = 24 Hr Aux
04 = Interior Follower 09 = Fire
05 = Trouble Day/Alarm Night 10 = Interior w/Delay
Choices For System Operation:
20 = Arming-Stay 39 = Fire Zone Trouble
21 = Arming-Away 40 = Bypassing
22 = Disarming 41 = AC Power Failure
31 = End of Exit Time 42 = System Battery Low
32 = Start of Entry Time 43 = Communication Failure
33 = Any Burglary Alarm 44 = RF Low Battery
34 = Code + # + 7 + 1 45 = Polling Loop Failure
35 = Code + # + 7 + 2 51 = RF Receiver Failure
36 = At Bell Timeout*** 52 = Kissoff
37 = 2 Times Bell Timeout*** 54 = Fire Zone Reset
38 = **Chime 58 = Duress
60 = Alarm Verification (use for both
START and STOP)
** Should be used to start 2-second close of relay only
***Or at Disarming, Whichever occurs earlier
Additional Stop Choices:
55 = Disarm + 1 Minute
56 = XX Minutes (Enter XX at 1*74)
57 = YY Seconds (Enter YY at 1*75)
START STOP
ACTION DESIRED A E V Z L Z T P Z L Z T P
TURN ON LIGHTS
On Entry:
Close relay at start of entry time and reset with key entry of
security code + # + 7+1 *
20032X034X
Close relay at start of entry time and reset after 1 minute 2 0 0 32 X 0 55 X
Close relay after any burglary alarm and reset with key
entry of security code + # + 7 + 2.**
20033X035X
**Can be used to turn on lights in the event of a burglary
alarm...(NOTE: Response types 06, 08, and 09 will not
activate relay).
Turn All Lights off with entry of security code + # + 7 + 2* 2 0 0 00 X 0 35 X
*Can be used to turn off all lights in on a given X-10 House
and Unit Id
Pulse light on trouble condition to attract attention_ 3 3 X 00 X 0 22 X
Pulse Light on alarm to attract attention_ 3 1 X 00 X 0 22 X
Use a PIR to turn a light on for a pre-set time period*_ 2 2 X 00 X 0 56 X