Section 8.
VIDEO ALARM VERIFICATION (VAV)
This section provides only general information about the VAV option. Detailed
information is contained in the manual provided with the VAV Transmitter.
General Information A Video Alarm Verification (VAV) transmitter, such as the AT100 (or VT-1000), is
an add-on accessory that permits video imagery of the area where an alarm was
detected to be transmitted on standard switched network telephone lines to the
monitoring location for the purpose of alarm verification. This transmission occurs
on the same phone line and phone call on which the alarm is digitally
communicated to the monitoring location.
The VAV transmitter connects to the same telephone line as the control and it is
linked to a 4204 Relay Module and to the control's zone 5. The purpose of the
zone 5 connection is to postpone non-critical dialer reports while the VAV
session is in progress. Note that zone 5 is then no longer available as a
protection zone when using the VAV. Zone 5 must be assigned a zone response
type (e.g. response type 10), and option 1*60 must be selected as 1. Option
1*67 must also be selected to assure that Contact ID report Event 609 will be
transmitted to the monitoring location after the alarm transmission.
VAV Operation As soon as an alarm is detected, a zone list should activate a 4204 relay that alerts
the VAV transmitter to freeze the video for the time just prior to the alarm (pre-
alarm) in its memory. After all messages have been sent to the primary phone
number during a reporting session, the control will transmit the VAV report (609)
to a 685 (revision 4.7 or higher) and then activate a second 4204 relay to activate
the VAV transmitter's transmission mode.
Once this triggering occurs, the control gives up the phone line to the VAV
transmitter without breaking connection with the central station. When the VAV
indicates via its connection to zone 5 that the video alarm verification session is
ended, dialer transmissions will be allowed to occur.
If a new fire alarm should occur during a session, the control will break the phone
connection and send the new fire alarm report. All other dialer messages
triggered during the session will be held until the session ends. It is imperative
that the second relay be set to choice 60 = Alarm Verification during Relay
Programming for both START and STOP conditions.
+-++-++- ++-++-++- +-+ - + -
VIDEO
OUT
876 54321
}
CAM 8
CAM 5
CAM 4
CAM 7
CAM 2CAM 6
CAM1
CAM 3
SEND
CANCEL
OPTIONAL CAMERA BACKUP POWER
If camera is connected to the DC OUT terminals,
the camera will operate in case of power failure if
the transmitter is connected to controls auxiliary
power or to a battery backup. Two cameras can
be connected to each pair of DC OUT terminals.
+
-
POWER INPUT
See Power Connections
section of manual
DC In and Backup Battery
Data In
Data Out
ECP
Red
Blk
Grn
Yel
Com
N.O.
N.C.
BUSY
Tip
Ring
Ring
Tip
EARTH GROUND
-
OPTIONAL CONNECTION TO
CONTROLS AUXILIARY POWER
TO PREMISES
HANDSET WIRES
REMOTE CAMERA VIDEO CONNECTORS
{
DC Out for cameras
REMOTE CAMERA
LOCAL MONITOR
(OPTIONAL)
CAMERA TRIGGER TERMINALS
NOT USED
NOT USED
BUSY TO CONTROLS
ZONE 5 TERMINALS
VT-1000 VIDEO TRANSMITTER
PHONE CONNECTIONS
COM
N.O.
N.C.
4204 RELAY MODULE
TYPICAL
CAMERA TRIGGER CONNECTION
COM
N.O.
N.C.
TYPICAL
SEND TRIGGER CONNECTION
1k res.
1k res.
GREEN
(TIP)
RED
(RING)
INCOMING
PHONE LINE
CONTROLS TERMINAL BLOCK
(4140XMPT2 TERMINALS SHOWN)
(SUPPORTS UP TO 8 CAMERAS)
COM
N.O.
N.C.
COM
N.O.
N.C.
RELAY 1
RELAY 2
RELAY 3
RELAY 4
TO CONTROLS
KEYPAD TERMINALS
Program the SEND trigger relay:
Action = 1 (close 2 sec.)
Start Event = 0 (not used)
Start Zone Type = 60 (2-way audio)
Stop Zone Type = 60 (2-way audio)
Program the camera trigger relay:
Action = 1 (close 2 sec.)
Start Event = 1 (alarm)
Start Zone List = n (desired zone
list number
)
A zone list must be
programmed which con-
tains all zones protected
by the camera being trig-
gered by this relay.
22
23
24 25 26 28 3027 29
21
12 13 14 15 16 18 2017 19
11
ZONE 5
2
3456 8 10791
FROM INCOMING
PHONE LINE
From Control
To Handset
EARTH
GROUND
KEYPAD TERMINALS
+
Data
IN
Data
OUT
+
DO NOT USE EOLR ON ZONE 5
TO
TRANSMITTER
PHONE
TERMINALS
TIP RING
}
}
}
}
}
}
}
}
}
}
}
}
}
}
}
}
}
}
}
}
}
}
{
4140XMPT2 CONNECTIONS TO THE VT-1000 VIDEO TRANSMITTER