– 18 –
Important! Fault
Annunciation
Since the polling loop and the RF receiver(s) are shared among the 8 partitions,
the scheme for annunciating their failure is as follows:
Respective faults (for zones 88-91 & 97) will report as trouble conditions only, and
as such, should be assigned either zone type 00 if no annunciation is desired, or
zone type 05 if annunciation as trouble condition is desired. If the polling loop or
RF link fails, the corresponding zone number will display a trouble condition for
each partition that uses the device that failed. In addition, all zones associated with
that device will indicate a fault condition. The trouble condition will not interfere
with the ability to arm the partition, but the faults must first be bypassed.
Compatible Polling Loop Devices
4208
Eight Zone Polling
Loop Expansion
Module
Used to supervise up to 8 hard-wired devices via the polling loop. NOTE: Does
not support 2-wire smoke detectors.
Set DIP switches to identify 8 zones.
The first two zones can be either normal or fast response (DIP switch selectable).
All zones are EOLR supervised (first six zones = 4.7k ohms, last two zones =
30k ohms), provided with the 4208.
4190WH
Two Zone Remote
Point Module
Used to supervise 2 hard-wired devices via the polling loop.
DIP switch programmable.
The left zone can be EOLR supervised, if necessary, and can accept either
open or closed circuit sensors, and can be set for fast response. The right zone
is unsupervised and can accept closed circuit sensors only.
4278EX
Quad Element Polling
Loop PIR
Quad element PIR with built-in RPM which is DIP switch programmable and
connects directly to the polling loop. Includes mirrors for both wide angle and
curtain/long range applications. Features an auxiliary sensor loop that permits
connection of another nearby closed circuit alarm sensor (reed contact, etc.).
4275EX
Dual Element Polling
Loop PIR
Dual element PIR with built-in RPM which is DIP switch programmable. Includes
mirrors for both wide angle and curtain/long range applications and can use the
1875PA Pet Alley mirror. Built-in selectable pulse count capability.
4194
Surface Mounted Reed
Contact (Wide Gap)
Wide gap surface mounted reed contact with built-in RPM, which is DIP switch
programmable.
4297
Polling Loop Extender
Module
Can be used if the 2-wire polling loop must be greater than the recommended
length (4000' [1220m] max). By installing a 4297 at the end of the first loop, the
polling loop can be continued. If more than 64mA needs to be drawn from the
polling loop to power RPMs, use of the 4297 provides another loop with 128mA
available.
Connects to the polling loop and is powered from auxiliary power.
4192SD
Photoelectric Polling
Loop Smoke
Detector
One piece photoelectric smoke detector with built-in RPM which is DIP switch
programmable.
4192SDT
Photoelectric Polling
Loop Smoke Detector
w/Heat Detector
One piece photoelectric smoke detector with 135°F (57°C) heat detector, and
built-in RPM which is DIP switch programmable.
4192CP
Ionization Smoke
Detector
One piece products of combustion ionization detector with built-in RPM which is
DIP switch programmable.
4139SN
Auto Smart Surface
Mount Reed Contact
Compact surface mount magnetic reed contact with built-in RPM.
Serial number ID "learned" by control panel.
Check product availability.
4191SN
Auto Smart Recessed
Reed Contact
Recessed (1/2" [13mm] dia.) magnetic reed contact with built-in RPM.
Serial number ID "learned" by control panel.
Check product availability.