Partition-Specific Field
Descriptions
(continued)
* 2 2 Console Panic Enables
Enter 1 to enable the appropriate console panics used in this partition.
Otherwise enter 0.
* 2 3 Multiple Alarms
Determines whether or not more than one alarm can be sounded in a given
zone during an armed period. Note that multiple alarm soundings will not
occur more frequently than allowed by the programmed alarm sounder
duration. This selection applies to local sounding and has no impact on the
number of communication messages transmitted. Refer to Swinger
Suppression for limiting communication messages. Enter 1 if this feature is
desired. Enter 0 if not desired.
*29 Quick Arm
Enter 1 to enable arming of the burglary system in AWAY, STAY, INSTANT
or MAXIMUM modes by using the # key instead of the security code. When
armed, reports closing as User 0 if open/close reporting for User #2
(typically a master level user) was enabled for a given partition. Enter 0 if
Quick Arm is not desired. (The security code must always be used to disarm
the system.) Note that if quick arm is used, the installer code and authority
level 5 code cannot disarm the system.
* 3 2 Primary Subscriber Acct #
Enter a 3 or 4 digit (depending on report format) primary subscriber account
number 00-09; B-F (11-15). Each number requires a 2-digit entry so as to
allow entry of hexadecimal digits (B-F). If a 3 digit account number is to be
used, only enter data in the first 3 locations, leaving the last one unfilled, by
entering a *.
* 3 8 Inhibit Bypass Of A Zone
Entering a zone number (01-87) prevents that zone from being bypassed
by the user. Enter 00 if this feature is not desired (all zones can be
bypassed). This selection does not affect fire zones, which the system
prevents from being bypassed.
* 3 9 Enable Open/Close Report For Installer Code
Enter 1 if open/close reporting for the installer is desired. Otherwise enter 0.
* 8 4 Intermittent Sensor Suppression
This option limits the number of messages (Alarms or Troubles) sent for a
specific channel in an armed period (Intermittent Sensor Suppression). Enter
01-15. If 00 is selected, all Alarm or Trouble codes are reported.
* 8 5 Enable Dialer Reports For Panics & Duress
Enter 1 for each panic/duress for which reporting is desired.
*87 Entry Warning
Enter 0 for 3 short beeps, or 1 for slow beeps that continue for the entire
entry delay period.
* 8 8 Burg. Alarm Comm. Delay
Enter 0 for no delay on burglary alarm communication, or 1 for 16-second
delay (no delay on 24-hour reports).
* 9 0 Secondary Subscriber Acct #
Enter the 3 or 4 digit number (depending on report format) for the
secondary subscriber account, 00-09; B-F (11-15). Each number requires a
2-digit entry so as to allow entry of hexadecimal digits (B-F). If a 3-digit
number is to be used, only enter data in the first 6 locations, leaving the last
two unfilled. Default=15 15 15 15. Erase the field by entering *90*. NOTE:
This field must be programmed if a secondary phone number is used (field
*34). This account number can be the same as the primary account
number.