– 32 –
Section 3.
REMOTE CONSOLES, SOUNDERS
& PHONE CONNECTIONS
REMOTE CONSOLES
General The Control supplies up to 750 mA of auxiliary power for remote consoles, polling
loop devices and/or other auxiliary devices such as motion detectors or 4-wire
smoke detectors*.
The Controls support, independent of auxiliary power considerations, up to 16
addressable remote consoles (6128, 6139).
Up to sixteen (16) 6128 or seven (7) 6139 consoles can be powered from the
auxiliary power output provided that the total current drawn from this output does
not exceed 750 mA. Keep this in mind when adding remote consoles so you
don't overdraw current from the panel. This would result in a battery which does
not charge properly or possibly a tripped auxiliary solid state circuit breaker.
If the auxiliary load is determined to be greater than 750 mA, then additional
consoles can be powered from a separate power supply. Refer to the
POWERING ADDITIONAL CONSOLES paragraph for a diagram that shows how
to make connections to the separate power supply.
6128 Addressable
Fixed-Word Console
Equipped with a liquid crystal display (LCD) using 2-digit numerics for zone
identification, and a set of pre-designated fixed-word prompts, such as "READY",
"NOT READY", etc. for system status. Keys are backlit. A built-in warning sounder
is also included, eliminating the need for a separate indoor sounder. DIP switch
selectable ID number, which allows console to display status of the partition to
which it is assigned. 25mA current drain.
6139 Addressable
Alpha Console
The 6139 Remote Consoles are keypad addressable consoles, and feature a red
"ARMED" LED which lights when the system is armed, and a green "READY"
LED which lights when the system is ready to be armed (no zone faults present).
This console also features display backlighting. The keypad on this console is
located behind a decorative door, and is continuously backlit for ease in use. The
keypad also features special panic keys, labeled A, B, & C (the D key is not used),
which are the equivalent to the panic pairs of keys 1/✱, ✱/#, & 3/# respectively.
Note that these keys must be held down for at least 2 seconds to activate an
alarm.
The console can be surface mounted directly to a drywall, or to a single or double
gang electrical box. For flush mounting to drywall, use the optional 6139TRK
flush mount kit.
100mA current drain.