UsEn@Test Mod. After the installationis completed, the Security System should be thoroughly
testedon a partitionby partltlcnbasisas follows:
1, With the System in the disarmed state,
checkthat all zones are Intact, If *
DISARMED - Press [*] to show faults b displayed, press the ~] key to display
the descriptors of the faulted zone(s), Restore faulted zone(s) If necassary, so
that *“’DISARMEIY** READY TO ARM Is displayed,
2, Enter the security code and press the TEST key, The external sounder (If
used) should sound for 3 seconds
and then turn off (the system Is operating
on the back-up battery only at this time).
NOTE 1, If the sounder does not sound, this maybe an indication that the backup
battery Is discharged or missing.
NOTE 2, As a reminder that the system is kr the Test mode, the Console will
sound a single beep at 15-second intervals if no protection zones are violated.
NOTE 3, In the Test mode, no alarm reports will be sent to the central statbn,
Alec, the external sounder (if used) will not be activated,
Doors and Windows
Open and close each protected door
and window in turn. Each action should
produce three beeps
from the Console, The descriptor for each prctectbn zone
will appear on the Console display.
Motion Detectors
Walk in front of any interior motion detectors, Listen for three beeps
when the
detector senses movement. While it is activated, its descriptor will remain
displayed on the Console. Note that wireless PIRs will have a 3 minute lockout
between transmissionsto conserve battery life (remove cover for walk test to
overridethe 3-minute lock-out).
Smoke Detectors
Followthe test procedureprovidedby the manufacturerof each smoke detector _
to ensure that all detectors are operational and are functioning properly.
NOTE: A 2-wire smoke detector display will not clear until the Test mode is exited.
Turning Off TEST mode
Enter
the securitycode and pressthe OFF key.
Armed System Test
iMPORTANT! A message wili be sent to the centrai station during the foiiowing
tests.
Notify the centrai station that a test will be in progress.
NOTE: A display of “COMM. FAiLURE” indicates a failure to communicate (no
Kissoff by the receiver at the central station after the maximum number of
transmission attempts is tried). if this occurs, verify that the phone iine is
connected, the correct report format is programmed, etc.
1.
2.
3.
Arm the system and fault one or more zones. Siience aiarm sounder(s) each
time by entering the code and pressing OFF.
Check that Entry/Exit deiay
zones
provide the assigned deiay times.
Check the keypad-initiated aiarms, if programmed
in fieid ’05, by pressing the
Panic key pairs (~] + [1], [#] + [3], ~]+ [#]). if the system has been programmed
for audibie emergency, the consoie wiil emit a ioud, steady aiarm sound. The
word
ALARM and a descriptor “99” wiii be displayed for ~] + [#]. (if ~] + [1] is
pressed, a “95”
wiil be dispiayed; if [#] + [3] is pressed, a “96 wiii be
displayed). Siience the aiarm by entering the security code and pressing OFF.
if the system has been programmed for siient panic, there wili be no audibie
aiarms or dispiays. A report will be sent to the centrai station, however.
Notify the central station that aii tests are finished and verify results with them.