Important! Fault
Since the polling loop and the
RF receiver(s) are shared among the 8 partitions,
Annunciation
the scheme for annunciating their failure is as follows:
Respective faults (for zones 88-91 & 97) will report as trouble conditions only, and
as such, should be assigned either zone type 00 if no annunciation is desired, or
zone type 05 if annunciation as trouble condtiion is desired. If the polling loop or w
RF link fails, the corresponding zone number will display a trouble condition for
each partition that uses the device that failed. In additiin, all zones associated with
that device will indicate a fault condition. The trouble condition will not interfere
with the ability to arm the partition, but the faults must first be bypassed.
Compatible Poiiing Loop Devices
4208
Eight Zone Poiling
Loop Expansion
Module
4190WH
Two Zone Remote
Point Moduie
4278
Quad Element Poliing
LooP PIR
4275
Duai Eiement Polling
Loop PiR
4194
Surface Mounted Reed
Contact (Wide Gap)
4197
Polling Loop Extender
Moduie
4192SD
Photoelectric Poiling
Loop Smoke
Detector
4192SDT
Photoelectric Poiling
Loop Smoke Detector
w/Heat Detector
4192CP
ionization Smoke
Detector
4139SN
Auto Smart Surface
Mount Reed Contact
4191SN
Auto Smart Recessed
Reed Contact
“ Used to supervise up to 8 hard-wired devices via the polling loop. NOTE: Does
not support 2-wire smoke detectors.
● Set DIP switches to identify 8 zones.
● The first two zones can be either normal or fast response (DIP switch selectable).
● All zones are EOLR supervised (first six zones = 4.7k ohms, last two zones =
30k ohms), provided with the 4208.
● Used to supervise 2 hard-wired devices via the polling loop.
c DIP switch programmable.
● The left zone can be EOLR supervised, if necessary, and can accept either
open or closed circuit sensors, and can be set for fast response. The right zone
is unsupervised and can accept closed circuit sensors only.
s Quad element PIR with built-in RPM which is DIP switch programmable and
connects directly to the polling loop. Includes mirrors for both wide angle and
curtain/long range applications. Features an auxiliary sensor loop that permits
connection of another nearby closed circuit alarm sensor (reed contact, etc.).
c Dual element PIR with built-in RPM which is DIP switch programmable. Includes
mirrors for both
wide angle and curtain/long range applications and can use the
1875PA
Pet Alley mirror. Built-in selectable pulse count capability.
c
Wide gap surface mounted reed contact with built-in RPM, which is DIP switch ~
programmable.
\
● Can be used if the 2-wire polling loop must be greater than the recommended
length (4000’ max). By installing a 4197 at the end of the first loop, the polling
loop can be continued. If more than 64mA needs to be drawn from the polling
loop to power RPMs, use of the 4197 provides another loop with 64mA
available.
● Connects to the polling loop and is powered from auxiliary power or by a
separate 729 power supply with battery backup.
“ One piece photoelectric smoke detector with built-in RPM which is DIP switch
programmable.
● One piece photoelectric smoke detector with 1350F (57°C) heat detector, and
buitt-in RPM which is DIP switch programmable,
● One piece products of combustion ionization detector with built-in RPM which is
DIP switch programmable.
● Compact surface mount magnetic reed contact with built-in RPM.
● Serial number ID “learned” by control panel.
● Check product availability,
● Recessed (1/2” dia.) magnetic reed contact with built-in RPM.
● Serial number ID “learned” by control panel.
● Check product availability.
-16-