Remote Console
An optional Amseco PAL 328N can be used for installations where it is desired to
Sounder Operation &
remote the sounds produced by the console’s built-in piezo sounder for one
Wlrlng
partition. The panel will remote all sounds (Le. alarm, trouble, chime, entry/exit,
etc.) produced by the console’s built-in sounder except for the short clicks
associated with console key depression. One applicatbn of this feature might be
to produce chime sounds in a bcation which is distant from the panel’s consoles.
This can also be accomplished using relay outputs (see Output Relay section).
If used, program field 1●46 must be set to “2” to enable the remote console
sounder option, and the Amseco piezo must be connected between the panel’s
auxiliary power and the J7 connector trigger output as shown below.
In addition, field ●15 must be used to select the partition whose console sounds
are to trigger the sounder. Zone 7 must be assigned to be a keyswitch zone
(even if keyswitch is not used).