Remote Keyswitch
If the keyswitch option is selected (field ●15), the alarm trigger outputs are
disabled.
An optional Remote Keyswitch can be used for remote arming and disarming of
the system. Note that keyswitch arming may only be used in one ~
E ‘artiti”n”
If used, program field ●15 must be set to the desired partition to enable the
keyswitch option, and the4146 keyswitch’s normally open momentary switch and
LEDs must be connected to Zone 7 and to the J7 connector trigger outputs
respectively. A 2k EOL resistor must be connected across the switch regardless
of whether or not zones 2-8 are selected to use EOL resistors. See diagram
below.
Note that the system automatically assigns zone type 10 to zone 7 if keyswitch is
used.
A momentary short across this zone will arm the system in the “AWAY” mode. If
the short is held for more than 3 seconds, the system will arm in the “STAY”
mode. (i.e. all zones designated as zone types 4 or 10 will be automatically
bypassed). After the system has been armed, the next time zone 7 is shorted,
the system will disarm.
An optional closed-circuit tamper switch (model 112) can be wired in series with
zone 7, so that, if the switchplate is removed from the wall, the tamper wiil open,
disabling keyswitch operation until the system is next disarmed from the console.
Note:
Only one keyswitch with LEDs can be supported by the system’s
power supply.
Note:
Open/close reporting for keyswitch is enabled in field ’40, and the
keyswitch reports as user O.
LED indications are defined as follows:
Green
Red
Meaning
off
off
Disarmed & Not Ready
On
off
Disarmed & Ready
off On Steady
Armed Away
*
off Slow Flash
Armed Stay
off
Rapid Flash Alarm Memory
i f I I
I i 2 3A 567 8 9
—l——r ~--
TO AUX POWER
TERMINAL 6
IF KEYSWITCH IS USEO.
1] OUT 1 CAN STILL BE USED TO PROVIDE
GROuND START, OPENicLOsE {SEE FIELD I. 46}.
2) OUT 2,3,4 NO LONGER PROVIDE ALARM
STATUS lNOICATIONS OUT 2 & 4 OPERATE
KEYsWITCH LEDs OUT 3 IS NOT USED.
ONLY 1 KEYSWITCH CAN BE USEO.
3) ZONE 7 IS NO LONGER USA6LE AS ,4
PROTECTIVE ZONE.
TO ZONE 7
TO TERM. 20
s
14
TO TERM 19
BROKEN LINES REPRESENT
INSTALLER WIRING CONNECTIONS
m
I
(
Ii
“-*’20”1-
.—.——.—-———--—-—
TAMPER
SWITCN IN. C.)
--—. --
63!
--—
LOCK
SWITCH IN 0.)
I
o
I
---- --
++---;
I 1----
I
2000
I
OHMS
L------ $
EOLR
--
-24-
1
1
4146 KEYSWITCH
(NOT UL LISTED)