EXTERNAL SOUNDERS
Relay Output
UL Household
Installations
Non-UL Installations
Compatible Sounders
702
Outdoor Siren (not UL
Listed)
719
Compact Outdoor
Siren (not UL Listed)
740
High intensity Sounder
747
indoor Siren
ABB1031
Motor Beii & Box
PA400B
(beige)/PA400R (red)
indoor Piezo Sounder
The Control provides a wet beli relay output which is used to power externai aiarm
sounders. Connections are made to terminais 4 (positive output) and 5 (negative
return). See SUMMARY OF CONNECTIONS Diagram.
-
For installations which must provide (JL Listed protection, the total wrrent drawn
from this output and the auxiliary power output, combined, must not exceed
750mA in order to wmply with the battery independence requirements. if two
System Sensor PA400 piezo alarm sounders, wired in parallel, are used (24mA
total),then (750MA - 24mA=) 726MA isavailable for auxiliary output use.
For non-UL installations, the total current drawn from this output can be up to 2.8
amps. A battery must be installed since current in excess of 750mA is suppiied by
the battery. Up to two 702 sirens can be used, wired in series. Up to two 719
sirens can be used wired in parailel.
iMPORTANT: Going beyond the above mentioned limits will overload the
power supply or may possibly trip the beli output cirwit protector.
● Self-contained siren (driver built-in) and weatherprmf for outdoor use. Can be
wired for either a steady or yeip sound and is rated at 120 dB @ 10 feet. This
siren can also be tamper protected, or can be mounted in a metal cabinet (716),
which can be tamper protected.
● Compact, self-contained siren (driver buiit-in), and weatherproof for outdoor
use. Can be wired for either a steady or yelp sound, and is rated at 90 dB @ 10
feet. A 708BE cabinet is available, which can be tamper protected if necessary.
● Compact high intensity sounder rated at 123 dB @ 10 feet. This sounder emits
an ‘ear piercing”, high frequency sound. Th”~ sounder can be mounted indoors
(bracket included) or outdoors (in 708BE cabinet).
● Attractive, self-contained indoor siren (driver built-in), provides steady or warble
tones and is rated at 95dB @ 10 feet.
● AMSECO motor bell& box, rated at 81 dB @ 10 feet.
k
● System Sensor indoor piezo sounder (red or beige), rated at 90 dB @ 10 feet.
UL NOTE: Use only UL Listed sounding devices for UL installations.
PHONE CONNECTIONS
Phone Line incoming phone tine and handset wiring is connected to the main terminai biock
Connections as follows (referto SUMMARY OF CONNECTIONS Diagram):
TB1
-26: Local Handset (TIP)
TB1-27: Local Handset (RING)
TB1-28:
Incoming Phone Line (TIP)
TB1-29: IncomingPhoneLine(RING)
If it is desired to connect the panel to phone lines that require ground statl
capability, then a 675 Ground Start Module must be used. This moduie is
trggered by one of the outputs on the connector Iabeied J7 (see VOLTAGE
TRIGGERS section).
Warning
To prevent the risk of shock, disconnect phone lines at teica jack before servicing
the panel.
PABX
If the communicator is oonnected to a telephone line inside a PABX, be sure the
PABX has a back-up power supply that can support the PABX for 24 hours. Many
PABXS are not power backed up and connection to such a PABX wili result in a
communication failure if power is lost.