ADEMCO 4140XMPT2 Manual de usuario Pagina 50

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 68
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 49
4+2 Hxpress
ADEMCO’S Express format provides the same information as the 4+2 format, but
with three differences:
1. The data is transmitted in DTMF (Dual Tone Multi-Frequency, known as ..-
“TouchTone”, at the rate of 10 characters per second). This greatly decreases
the time it takes a report to go through to central station. An average 4+2 Low w
Speed report might take as long as 20 seconds to complete its report, but
4+2 Express takes under 3 sees.
2. Two message rounds are eliminated by the use of a checksum digit. Instead
of the communicator sending 2 rounds per report, it sends only 1 round with
a checksum digit at the end. Doing this also helps in decreasing the time it
takes for a report to be sent.
3. The handshake frequency is 1400 Hz followed by 2300 Hz, and the kissoff
frequency is 1400
Hz.
Memco High Speed
ADEMCO’SHighSpeedformattransmitsdata in DTMF at a rate of 10 characters per
Reporting second. The handshake frequency is 1400 Hz followed by 2300 Hz, and the
kissofffrequencyis 1400 Hz. The messagecontains13 digitsas follows: A 4-digit
accountnumber + eight channelsof zone information(l-8 or duressplus 9-15) +
one statuschannel,whichidentifiesthe type of events being reported in the eight
zone locations. Atypical High Speed report will be kissed off in under 5 seconds.
Channels 1 through 8 could have one of the following conditions:
1 = NEW EVENT
2 = OPENING (Status Channel Always= 2)*
3 = RESTORE
4 = CLOSING (Status Channel Always= 4)*
5 = NORMAL, NO EVENT TO REPORT
6 = PREVIOUSLY REPORTED, NOT YET RESTORED
NOTE: Channel 1 will contain the user ID 1-9, A-F if Open/Close reporting is
enabled.
The status channel might have one of the following conditions:
1 =
DURESS (For Duress Plus Channels 9-15 Only)
2 = OPENING
3 = BYPASS (For Channels 1-8 Only)
4 = CLOSING
5 = TROUBLE (For Channels 1-8 Only)
6. SYSTEM STATUS: sAC LOSS in Channel 1
LOW BAITERY in Channel 2
PROGRAM TAMPER in Channel 3
POWER ON RESET in Channel 4
7. NORMAL ALARM STATUS (Chnls 1-8 Only)
9 = TEST REPORT
A typical high speed report may look as follows:
123451155555 7(Acct#1234 with alarms on channels 2 and 3)
High Speed Format Limitations
1. When using Ademco high speed, remember there are only 15 channels
available,plus a duress channel. If more than 15 zones are being used, they will
have to share channels.
2. With Ademco High Speed reporting, channels 9-15 cannot report troubles or
bypasses.
Use these channels for zones that will not report these conditions.