Programming The
Consoies
Mounting The
Consoies
Wiring Consoies
Powering Additional
Consoies
The consoles can beset for an address of 0-30
iMPORTANT! You must select an address of O, 1, 2, or 3 if standard defaults
are to be programmed, since these are the only console addresses enabled by
the standard default. Refer to the addressable console DIP switch table at the
end of this manual to set the 4137AD and 5137AD address ID number. Refer to
the instructions provided with the 6139 to set its ID number.
Do not use address 31 with the 4140XMPT2. Address 31 causes the
console to operate in non-addressable mode (i.e. works like a standard, non-
addressable console).
Consoles must also be programmed for type, partition number and console
sounder suppression options. Refer to the PROGRAMMING GUIDE (#93 MENU
MODE-DEVICE PROGRAMMING) for instructions.
Note that fiekf wiring to the consoles must be completed before the consoles can
be mounted.
The consoles can be either surface mounted or flush mounted (using an
appropriate Trim Ring Kit: 5137TRK or 6139TRK). Refer to the mounting
instructions and template included with the console and/or trim ring kti for specific
information.
Be sure to take the height of the users into account when mounting consoles.
Consoles may be wired to a single wire run or individual consoles may be
connected to separate wire runs. The maximum wire run length from the panel to
a console which is homerun back to the panel must not exceed:
Wire Guage
Maximum Length
#22gauge
450feet
#20gauge
700feet
#18gauge 1100feet
#16gauge
1750feet
NOTE:The
lengthofall wiremnsoombinadmustnot
excsad2000feetwhenunshieldedquadconductoroabls
isused(1OCOfaatifshieldadtie isused.)
If morethanoneconsoleis wiredto a run,thenthe
abovemaximumlengthsmustbedvkfad thenumber
Y!
ofconsolesontherun(i.e.themaximumen thwould
be225
feet iftwo oonsolasarewiredona # 2gauge
Nn),
Up to twelve 4137AD or eight (8) 5137AD or seven (7) 6139 consoles can be
powered from the auxiliafy power output provided that the 750mA rating is not
exceeded. The backup battery will supply power to these consoles in the event
that AC power is lost.
Additional consoles can be connected to the system by using a regulated,
12VDC power supply (eg. 487-12 supplies 12V, 250mA; 488-12 supplies 12V,
500mA). Use a UL Listed, battery backed supply for UL installations. Note that the
maximum number of consoles supported by the system is 16.
Connect additional consoles as shown below, using the console wire colors
shown. Make sure to observe the current ratings for the power supply used.
Wire run lengths from the 4140XMPT2 to consoles are listed in the WIRING
CONSOLES paragraph (maximum combined wire run lengths for all consoles
must not exceed 2000, or 1000 if shielded cable is used).
IMPORTANT: Make connections directly to the screw terminals as shown. Make
no connection to the wnsole blue wire.
The 487-12/488-12 power supplies have a backup battery which can power
these consoles in the event of AC power loss. Note that consoles powered from
supplies which do not have a backup battery will not function when AC power
is lost. In this case, make sure to power at least one console from the Control’s
auxiliary power output.
-31-