ZONE TYPES & APPLICABLE SENSORS
Type 00
Zone Not Used
Type 01
Entry/Exit #1 Burglary.
Type 02
Entry/Exit #2 Burglary.
Type 03
Perimeter Burglary.
Type 04
Interior, Follower.
Type 05
Trouble by Day/Alarm
by Night.
The 4140XMPT2 supports up to 87 zones of hard-wire, polling loop and/or
wireless protection, distributed among up to 8 partitions. The following table lists
the zone numbers and the types of sensors that can be used with each in this
system:
one
Sensors
1
2-wire smoke detectors (if used)
7 keyswitch (if used)
8
latching type glass break detectors (if used)
1-9
traditional hard-wired zones
1-63 5700 eeries wirelees devices
1-87 5800 series wireless devices
10-87 polling loop devices
95
“/1 panic
96 #13panic
99
/# panic
Each zone must be assigned to a zone type, which defines the way in which the
system responds to faults in that zone.
In addition, there are three keypad
activated zones (PANIC keys, see note below) for each partition, a polling loop
supervision zone, and four RF supervisory zones, two for each RF Receiver
installed, Zone types are defined below.
Program a zone with this zone type if the zone is not used,
This zone type provides entry delay whenever the zone is faulted if the control is
armed in the Away or Stay modes. When the panel is armed in the Instant or
Maximum modes, no entry delay is provided. Exit delay begins whenever the
control is armed, regardless of the arming mode selected. These delays are
programmable. This zone type is usually assigned to sensors or contacts on
doors through which primary entry and exit will take place.
This zone type provides a secondary entry delay whenever the zone is faulted if
the
panel is armed in the Away and Stay modes. When the panel is armed in the
Instant or Maximum modes, no entry delay is provided. Secondary exit delay
begins whenever the control is armed, regardless of the arming
mode selected.
These delays are programmable. This zone type is usually assigned to sensors or
mntacts on doors through which secondary entry and exit will take place, and
where more time might be needed to get to and from the console. Delay time must
be greater than Zone type 1. (Ex.: a garage, loading dock, or basement door)
This zone type gives an instant alarm if the zone is faulted when the panel is
armed in the Away, Stay, Instant or
Maximum modes. This zone type is usually
assigned to all sensors or contacts on exterior
doors and windows.
This zone type gives a delayed alarm (using the programmed Entry/exit time) if
the Entry/Exit zone is faulted first. Otherwise this zone type gives an instant
alarm. This zone type is active when the panel is armed
in the Away or maximum
modes. Maximum mode eliminates the delay though. This zone type Is
bypassed automatically when the panel Is armed In the Stay or
Instant modes. This zone type is usually assigned to a zone covering an area
such as a foyer, lobby, or hallway through which one must pass upon entry (After
faulting the entry/exit zone to reach the console to disarm the system.) Since this
zone type is designed to provide an instant alarm if the entry/exit zone is not
violated first, it will protect an area in the event an intruder hides on the premises
prior to the system being armed, or gains access to the premises through an
unprotected area.
This zone type will give an instant alarm if faulted when armed in the Away, Stay,
Instant or Maximum (night) modes. During the disarmed state (day), the system
will provide a latched trouble sounding from the console (and a central station
report, if desired). This zone type is usually assigned to a zone which contains a
foil-protected door or window (such as in a store), or to a zone covering a
“sensitive” area such as a stock room, drug supply room, etc. This zone type can
also be used on a sensor or contact in an area where immediate notification of an
entry is desired.
-11-