Mode Features For Each Arming Mode
Exit
Entry Perimeter Interior
Delay
Delay
Armed Armed
AWAY Yes Yes
Yes
Yes
STAY Yes
Yes Yes No
INSTANT Yes No
Yes
No
MAXIMUM
Yes No
Yes
Yes
Access Control If programmed, one relay maybe used for access oontrol. To activate this relay,
the user enters his user code + [0]. The relay will pulse for 2 seconds.
Delay Closlng Time If open/close schedules are used, end users can manually extend the closing
window by up to
2 hours. This is useful if a user must stay on the premises later
than usual. User must have authority level of manager or higher.
To extend the closing window, enter user code + # +82, The following will be
disDlawd.
EE!EI
Enter the number hours, 1 or 2, by which the end of the
closing window should be delayed. Note that the delay is
from the scheduled closing time, not from the current time.
Press
● to acoept entry and exit this mode. Press # to exit this
mode without changes.
The system will send a “Schedule Changed” message to the
central station when the closing window is delayed.
Important: The delay cannot be reduced onoe it is set. It can
only be increased. This is to prevent the user from deleting
the delay after the normal window expires, thereby missing
the end of the window.
Partition “GotoM Each console is assigned a default partition for display purposes, and will show
Commands
only that partition’s information. To see information for another partition, or
perform system functions in another partition, use the GOTO command (code+
~] +pattition number O-8). The oonsole will remain in the new partition until
directed to go to another partition, or until 120 seconds has elapsed with no
keypad activity.
View Capabllltles Of A
The console will display the partitions that user is authorized for, the user
User
number, and the authority level for all partitions authorized. Enter oode + [X] +
[x]. The user’s capabilities in each authorized partition will typically be disp~y~
as follows:
m
The user’s Open/Close report capability is shown by the dot following the
authority level. If Open/Close is not enabled for a user, the dot will not appear.
Viewing Downloaded
Users may occasionally receive messages on the console display from their
Messages
installation oompany. When this occurs, the console will display “Message. Press
Ofor 5 sees.”. Instruot the user to press and hold the Okey to display the central
station’s message. Note that the system must be in the READY state to view
these messages.
Using The Built-in
An abbreviated User’s Manual is stored in the system’s memory, and can be
Userls Manual particularly useful to the end user if the printed Usets Manual is not mnveniently
accessible when the user needs to perform a seldom used and unfamiliar system
procedure. The Built-in Usets Guide is displayed by simply pressing any of the
function keys (e.g., OFF, AWAY, STAY, MAXIMUM, BYPASS, INSTANT, CODE,
TEST, READY, #, and CHIME) for approximately 5 seconds and then releasing it.
Abbreviated instructions relative to the key that has been pressed will then be
displayed (2 lines of text are displayed at a time). This function operates in either
the armed or the disarmed state.
-43-