NOTE: All references in this manual for number of zones, number of user codes, number of access cards, and the
event log capacity, use the VISTA-250FBP’s features. The following table lists the differences between the VISTA-
128FBP and the VISTA-250FBP control panels. All other features are identical.
Feature VISTA-128FBP VISTA-250FBP
Number of Zones 128 250
Number of User Codes 150 250
Event Log Capacity 512 1000
The purpose of this document is to provide a quick and easy way to program your entire system. A recommended
programming procedure is included, followed by a list of program fields with the corresponding program group they belong to
(system-wide, partition-specific, scheduling, etc.). Two program forms are included. One contains all the programming fields,
and the other contains the partition-specific fields. If you are setting up a single-partition system, the partition-specific fields
become system-wide fields.
Following the program forms are system layout worksheets. We recommend that you use these sheets to plan your system
before programming is performed. If you need further information about specific programming options, see the
VISTA-
128FBP/VISTA-250FBP Installation and Setup Guide
.
Make sure that one two-line alpha keypad is connected to the control and is set to device address "00."
Single-Partition System
The system default is for a single-partition system. Use the VISTA-128FBP/VISTA-250FBP SINGLE PARTITION
PROGRAMMING FORM when programming for single-partition usage. Follow the steps outlined in RECOMMENDED
PROGRAMMING PROCEDURE of this document for proper programming procedure.
Multiple-Partition System
You must enter the number of partitions you are using in data field 2*00 to set the system for multiple partitions. Use the
VISTA-128FBP/VISTA-250FBP SINGLE PARTITION and the PARTITION-SPECIFIC PROGRAM FORMS when
programming the system for multiple partitions. Follow the steps outlined in RECOMMENDED PROGRAMMING
PROCEDURE of this document for proper programming procedure.
SUMMARY OF PROGRAMMING COMMANDS
• To enter program mode, enter installer code + [8] + [0] + [0] + [0]
• To set standard defaults, press ✱97
• To change to next page of program fields, press ✱94
• To return to previous set of fields, press ✱99
• To erase account and phone number field entries, press [✱] + field number + [✱]
• To assign zone descriptors, press #93 + follow menu prompts
• To add custom words, press #93 + follow menu prompts
• To enter Installer's Message, press #93 + follow menu prompts
• To exit program mode, enter ✱99 OR ✱98: ✱99 allows re-access to programming mode by installer code.
✱98 prevents re-access to programming mode by installer code. The only way to re-access programming
mode is by depressing both the [✱] and [#] keys at the same time within 30 seconds of power-up.
Standard default (✱97) values are shown in brackets [ ], otherwise default = 0.