– 10 –
*77 AUTO TROUBLE RESTORE [1]
0=disable, 1=enable
*79 ZONE TYPE RESTORE ENABLES FOR ZONE TYPES
1-8
1
2
3
4
5
6
7
8
1=enable; [0=disable]
*80 FOR TYPES 9, 10 and 14
9 10 14
1=enable; [0=disable]
Restores must be set to “1” for Commercial Fire installations.
*83 FIRST TEST REPORT TIME | | |
[Day 00; hour 12; min 00]. Days 01-07, Hours 00-23, Min 00-
59; 00 in all boxes = instant (Day 01= Monday)
*84 SWINGER SUPPRESSION [01] |
01-15 alarms
Must be "00" (disabled) for Commercial Burglary
*85 ENABLE DIALER REPORTS FOR PANICS & DURESS
1=enable; [0=disable]
995
996
999
Duress
*87 ENTRY WARNING [1]
1=continuous; 0=3 beeps
*88 BURG. ALARM COMM. DELAY [1]
1=30 seconds; 0=no delay
Must be "0" for Commercial Burglary installations. Must be “1”
for SIA installations.
*89 ALARM RESTORE REPORT TIMING [0]
0 = Restore is sent when zone is restored or at disarming,
whichever occurs first.
1 = Restore is sent at disarming whether zone is restored or
not, or at bell timeout, but only if restored.
2 = Restore is sent at disarming, whether the zone is restored
or not.
This field applies only to Burglary zone types. It does not
apply to Fire or Panic zone types.
Must be "2" for Commercial Burglary installations.
*90 SEC. SUBS. ACCT # | | | |
Enter 00-09; B-F (11-15) [15 15 15 15]
1*11
ZONE BYPASS AFTER DISARM
[00000000]
1
2
3
4
5
6
7
8
1=enable; 0=disable
Enter 1 for each partition in which zones will remain
bypassed after disarm.
NOTES:
For each partition in which field 1✳11 is enabled, the USER
CODE + OFF will no longer unbypass zones. To unbypass
ALL zones, you must enter USER CODE + # + 64. To
unbypass zones INDIVIDUALLY, you must enter USER
CODE + 6 + zone number.
Any zone that was automatically bypassed by the system will
be unbypassed upon disarming of the system (e.g., STAY
mode, Auto-STAY, etc.).
Vent zones and zones bypassed by a programmed Auto-
Bypass schedule (Timed Driven Event) are considered
“manual bypasses” and will not be unbypassed upon
disarming the system.
Zones that were in a bypassed state at the time a System
Shutdown is sent from the Compass Downloading software
will be unbypassed when the System Shutdown is removed.
1*12 PROGRAM NOTIFICATION SIGNAL [1]
1=yes; 0=no
Must be "1" for Commercial Fire installations.
1*13 SYSTEM SENSOR REVERSING RELAY – Not Used.
[0]
0=use neither Zone 1 or Zone 2 inputs; 1=use Zone 1 input;
2=use Zone 2 input; 3=use Zone 1 and Zone 2 inputs.
1*15
CANCEL VERIFY [1]
0=disable, 1=enable alarm output pulse upon kissoff of
Cancel report. NOTE: Field 1✳52 must be enabled to send a
Cancel report to the central station.
NOTE: Cancel reports must be enabled in system group 1.
1*17 LOBBY PARTITION [0]
Enter the "common lobby" partition (1-8)
1*18 AFFECTS LOBBY [0]
Enter 1 if this partition affects the common lobby;
Enter 0 if it does not.
Must be "0" for Commercial Burglary and Commercial Fire
installations.
1*19 ARMS LOBBY [0]
Enter 1 if arming this partition attempts to arm lobby;
Enter 0 if it does not.
Must be "0" for Commercial Burglary and Commercial Fire
installations.
1*20
EXIT ERROR LOGIC ENABLE [1]
0=No; 1=Bypass E/E and Interior zones faulted after exit
delay.
Must be "0" for Commercial Burglary installations. Must be
enabled “1” for SIA installations.
1*21
EXIT DELAY RESET [1]
0=No; 1=Resets Exit Delay to programmed value after zone
is closed and then faulted prior to end of exit delay.
Must be "0" for Commercial Burglary installations. Exit Delay
must be enabled “1” for SIA installations.
FIELDS 1✳22-1✳25: Allow four sets of two zones each to be linked
so that both must fault within a 5-minute period to cause an alarm.
Default for these fields = [000], [000].
1*22 CROSS-ZONING PAIR ONE | | | |
1*23 CROSS-ZONING PAIR TWO | | | |
1*24 CROSS-ZONING PAIR THREE | | | |
1*25 CROSS-ZONING PAIR FOUR | | | |
1*26 PANIC BUTTON OR SPEEDKEY
[00, 00, 00, 00]
|
A
|
B
|
C
|
D
Enter speedkey macro # (01-32) to use keys A-C for macro.
Otherwise enter 00 to use as panic. For D key, enter macro
# 01-32, or 00 to select macro when key is pressed.
1*28 RF TX LOW BATTERY SOUND [0]
1=immediate; 0=when disarmed
Must be 1 for UL installations.