Compatible Devices
Supports up to 8 Addressable Keypads: 6150 Fixed-Word Display Keypad, 6160 Alpha Keypad,
6150V Fixed-Word Display Voice Keypad, 6160V Alpha Display Voice Keypad, 6150RF
Keypad/Transceiver
Supports 4219, 4229 addressable hardwire zone expander modules (VISTA-20P = up to five for up
to 40 expansion zones; VISTA-15P = up to 2 for up to 16 expansion zones)
Supports 5881 series receiver and 5800 series transmitters
Output relays and/or Powerline Carrier Devices (X-10 type)
-- VISTA-20P = up to 16 relays/devices plus two on-board triggers
-- VISTA-15P = up to 8 relays/devices plus two on-board triggers)
-- Use any combination of 4204, 4229 and or Powerline Carrier Devices.
-- Output functions (up to 48)
Ademco 4285/4286 Phone Module (Part. 1 only); provides access to the system via on premises or
off-premises phones for arming, disarming, etc., plus control of relay outputs and Powerline
Carrier devices.
Audio Alarm Verification (using AAV module, such as Eagle Model 1250); can be used in
conjunction with an output trigger to permit voice dialog between an operator at the central station
and a person at the premises.
Alarm output provides a 12VDC, 2 AMP output that can drive the compatible sounders; steady
output for burglary/panic, or temporal pulse (3 pulses pause 3 pulses pause 3 pulses. . .) for
fire. Uses current limiting circuitry for protection.
Auxiliary Power Output: 12VDC, 600 mA maximum (uses PTC for protection).
Backup Battery: Rechargeable (sealed lead-acid type) 12VDC, 4AH minimum.
Long Range Radio: Primary telephone number messages can be reported via ECP connection to
various Long Range Radios (check compatibility and availability of specific models)
AC Power Supply: Plug-in 120VAC transformer, ADEMCO 1321 or, if using Powerline Carrier
devices, ADEMCO 1321X10 or 4300 Transformer Module
NOTE: All devices and accessories used in a Canadian installation must be Listed for use in Canada.
Important Installation Highlights (Installer Please Read)
This system uses addressable keypads and Zone Expander Modules (see table of addresses in
Programming Overview section).
Keypads must be set for addresses 16-23 (first keypad is address 16, which is different from
previous controls) and programmed in data fields *190-*196.
Zone Expander Modules must be set for specific addresses (07-11), based on the zone numbers used
(see table of addresses in 4219/4229 Expansion Zones section).
4204 Relay Modules must be set for specific addresses (12-15; see Connecting Relay Modules
section).
This control will not power-up unless AC power is connected (will not power-up on battery alone).
However, once the system is powered up, it will operate on battery power in the event of AC loss.
Relays have two programming menu modes: Use *79 Menu mode to map module addresses and
device (output) numbers. Use *80 Menu mode to define the output functions (see Output Device
Programming section).
This system supports programmable function keys. Use *57 Menu mode to define the function keys
(see Function Key Programming section).
This system provides various paging features. Refer to the Programming Overview section for a
summary on pager programming.
Installation and Setup Guide