SECTION 5
Zone Programming
(
56 and
58 Menu Modes)
••••••••••••••••••••••••••••••••••••••••••••••••••
About Zone Programming
56 Zone Programming is used to program zones, zone types, report codes, enroll 5800 RF Wireless
Transmitter serial numbers, and identify the type of loop input device(s). This mode can also be used
to enter alpha descriptors for programmed zones; however, we recommend entering descriptors in
menu mode
82 (
Alpha Descriptor Programming
after all zone programming has been completed).
For a faster method of zone programming, you can use the
58 Expert Programming Mode instead of
56 Zone programming. The
58 Expert Programming Mode is designed for those who have had
previous experience in programming control panels of this type.
NOTE: Alpha display prompts are shown in a double-line box.
56 Zone Programming Procedure
Zone Programming involves:
1. Entering the zone number to be programmed;
2. Making appropriate entries at the prompts;
3. Confirming the serial number of wireless transmitter zones.
Start Zone Programming mode by pressing
56 while in Data Programming mode. The following
prompts are displayed:
PROMPT VALID ENTRIES EXPLANATION
SET
TO CONFIRM?
0 = NO 1 = YES
Set to Confirm
0 = no
1 = yes
If 1 (Yes) is entered, you will be prompted to confirm each
transmitter after entering the serial and loop numbers (at the XMIT
TO CONFIRM prompt later in this procedure).
We recommend
that you confirm the programming of every transmitter.
Enter Zn Num.
(00 = Quit) 10
Zone Number
VISTA-20P:
wired zones 01-08
wireless zones 09-48
button zones 49-64
VISTA-15P:
wired zones 01-06
wireless zones 09-34
button zones 49-56
Both Controls:
91 = addr. device report enable
92 = duress report enable
95, 96, 99 =emergency zones
00 to quit
[
] to continue
Enter the zone number that you wish to program. Zone 10 has been
entered as an example in the display at left.
Enter a report code for zone 91 to enable addressable device
reporting.
Enter a report code for zone 92 to enable duress reporting.
95, 96, 99 are emergency (panic) key zones.
Zn ZT P RC In: L
10 00 1 10 RF: 1
OR
Zn ZT P RC In: AD
10 00 1 10 AW: 07
OR
Zn ZT P RC HW: RT
10 00 1 10 EL 1
Summary Screen
[
] to continue
A summary display appears.
IN: L appears for wireless zones and indicates input type and loop.
IN: AD appears for hardwire expansion zones (AW) and indicates
the modules address (AD), which is based on the zone number.
HW: RT appears for hardwire zones and indicates configuration
(EOL, NO, NC, zone doubling, double-balanced) and response time
selection.
5-1