01 Activated By:
Zone List
Activated By
0 = delete
1 = zone list
2 = zone type
3 = zone number
[
] to continue
Select where the initiating event for this output definition is to occur
as follows:
0 = delete (deletes the output function and any previous
programming;-see prompt below)
1 = zone list (go to A” prompt)
2 = zone type (go to B” prompt)
3 = zone number (go to C” prompt)
If you enter 0, the following prompt appears:
Delete?
Press 1 to delete this
0 = NO, 1 = YES
output definition
.
A
01 Zn List
1
Zone List
01-08 = zone list
[
] to continue
If zone list was selected, this screen appears. Otherwise skip to the
next row.
Enter the desired zone list number associated with this output
number.
NOTE:
Do not use pager zone lists 09-12 in output definitions.
Press [
] to continue.
Enter the zone list event that will activate this output.
Enter Event
0 = restore; 1 = alarm;
Alarm 1
2 = fault; 3= trouble
NOTE:
For alarm, fault, and trouble, an event on ANY zone in the
list activates the output, but ALL zones in the list must be restored
before the output is restored.
Press [
] to continue and skip to the Output Action prompt.
B
01 Enter Zn type
Perimeter 03
Zone Type
see list at right
If zone type was selected, this screen appears. Otherwise skip to the
next row.
Enter the desired zone type associated with this output number. See
below for a list of available zone types.
CHOICES FOR ZONE TYPES:
00 = Not Used 05 = Trouble Day/Alarm Night 12 = Monitor Zone
01 = Ent/Exit #1 06 = 24 Hr Silent 14 = Carbon Monoxide
02 = Ent/Exit #2 07 = 24 Hr Audible 16 = Fire w/verification
03 = Perimeter 08 = 24 Hr Aux 23 = No Alarm Response
04 = Interior Follower 09 = Fire 24 = Silent Burglary
10 = Interior w/Delay 77 = keyswitch zone
81 = AAV Monitor Zone
90-91 = Configurable
CHOICES FOR
SYSTEM OPERATION:
20 = ArmingStay 36 = **At Bell Timeout*** 52 = Kissoff
21 = ArmingAway 38 = Chime 54 = Fire Zone Reset
22 = Disarming 39 = Any Fire Alarm 58 = Duress
31 = End of Exit Time 40 = Bypassing 60 = AAV
32 = Start of Entry Time 41 = **AC Power Failure 66 = Function Key
33 = Any Burglary Alarm 42 = **System Battery Low 67 = Bell Fail
43 = Comm. Failure 68 = Telco line cut
78 = keyswitch red LED
79 = keyswitch green LED
** Use 0 (Any) for Partition No. (P) entry.
*** Or at Disarming, whichever occurs earlier.
Use *57 Menu Mode to assign the function key (function 07).
Note:
In normal operation mode:
Code + # + 7 + NN Key Entry
starts
Device NN.
Code + # + 8 + NN Key Entry
stops
Device NN.
Enter the partition in which this zone type will occur.
01 Partition 0 = any partition; 1 = partition 1;
Any partition 0 2 = partition 2; 3 = common
Press [
] to continue and skip to the Output Action prompt.
Installation Instructions
6-4