Hardwire Zones
Normally Open Zones/ Normally Open EOLR Zones
1. Connect open circuit devices in parallel across the
loop; for EOLR zones, connect the EOLR across the
loop wires at the last device.
2. Enable normally open/EOLR zones using Zone
Programming mode, Hardwire Type prompt.
Normally Closed Zones/Normally Closed EOLR Zones
1. Connect closed circuit devices in series in the high (+)
side of the loop; for EOLR zones, connect the EOLR in
series following the last device.
2. Enable normally closed/EOLR zones using Zone
Programming mode, Hardwire Type prompt.
Double-Balanced (V20P/PS only):
Connections as shown
(resistors not provided).
IMPORTANT:
Double-balanced zones provide zone tamper
protection, and should be used as burglary zones only. Do not
use double-balanced zones as fire zones.
Zone Doubling (V20P/PS only):
Connections as shown
(resistors not provided).
2k
2k
2k
ZONE 3
2k
2k
2k
ZONE 4
12 13
14
zone-002-V0
TAMPER
CONTACTS
TAMPER
CONTACTS
10 11
6.2k
ZONE 10
3k
ZONE 2
zone-004-V0
Double Balanced Zones Zone Doubling
Notes
EOLR:
If the EOLR is not at the end of the loop,
the zone is not properly supervised and the
system may not respond to an open on the zone.
Zone 1 is intended for EOLR only.
U
L
For UL commercial burglar alarm
installations, use normally closed zones.
Zone Doubling (VISTA-20P/PS only):
This feature provides two hardwired zones for each
standard hardwired zone connected to the controls
terminals (but does not increase the total number
of zones supported by the control). If enabled (Zone
Programming mode, Hardwire Type prompt,
option 3”), hardwire zones are automatically
paired as follows:
Zone Paired with zone
210
311
412
513
614
715
816
Note for Configurable Zone Types:
A short
across the EOL (i.e., at terminal) on either zone of
a zone-doubled pair or on a double-balanced zone
causes a tamper condition
.
Smoke Detectors
2-Wire Smoke Detectors
1. Connect up to sixteen (10, if clean me option used)
2-wire smoke detectors across zone 1 terminals 8 (+)
and 9 (-) as shown in the Summary of Connections
diagram at the back this manual. Observe proper
polarity when connecting the detectors.
2. Connect an EOL resistor across the loop wires at the
last detector.
Notes
Fire Verification (zone type 16):
The control
panel will verify a fire alarm by resetting the
smoke detectors after the first alarm trigger, and
then waiting 90 seconds for a second alarm
trigger. If the smoke detector or thermostat does
not trigger again, the control will disregard the
first trigger, and no alarm signal will occur. This
feature eliminates false alarms due to electrical
or physical transients.
SIA Installations:
If using fire verification on
zones other than zone 1, UL Fire Alarm Listed
relay accessories must be used to reset power as
described in step 3.
The zone 1 alarm current supports only one
smoke detector in the alarmed state.
Clean Me Option:
If enabled (field *174 = 1;
*56 zone programming, response time prompt =
3), certain ESL smoke detectors
send clean me
reports as appropriate. If used, the maximum
number of detectors is reduced to 10 (not
standard 16).
Refer to the ESL documentation included with
the smoke detector for information regarding
compatibility with the clean-me option.
Installation Instructions
2-6