FIELD TITLE and DATA ENTRIES EXPLANATION
*59
Exit Error Report Code
0 = no report
1-F = see description above
If the system is armed and an entry/exit or interior zone is still open
after the Exit Delay time has expired, an alarm will sound (keypad
displays EXIT ALARM). If the system is disarmed before the end of
the Entry Delay, the alarm sounding stops and no message is sent to
the central station. The keypad will display CA (Fixed-Word
display keypads) or CANCELED ALARM (Alpha display keypads).
If the system is not disarmed before the end of entry delay, and an
entry/exit or interior zone is still open, an EXIT ALARM message
will be sent to the central station if an Exit Error Report code is
entered. The keypad will display EA (Fixed-Word display keypads)
or EXIT ALARM (Alpha display keypads), and alarm sounding will
continue until the system is disarmed (or timeout occurs).
An Exit Alarm condition will also result if a fault occurs in an exit or
interior zone within 2 minutes following the end of the exit delay,
and an EXIT ALARM message will be sent to the central station.
With Contact ID format, the message will contain the zone number
and error code 374 (ALARMEXIT ERROR).
*60
Trouble Report Code
0 = no report
1-F = see description above *59
This will be sent if a zone has a trouble condition.
UL: Required for UL commercial burglar alarm installations and
required for residential fire alarm installations.
*61
Bypass Report Code
0 = no report
1-F = see description above *59
This will be sent when a zone is manually bypassed.
UL: Required for UL commercial burglar alarm installations.
*62
AC Loss Report Code
0 = no report
1-F = see description above *59
Timing of this report is random with up to a 4-hour delay. If AC
restores before the report goes out, there is no AC RESTORE
report.
UL: Required for UL commercial burglar alarm installations and
required for residential fire alarm installations.
*63
Low Bat Report Code
0 = no report
1-F = see description above *59
Sent when a low-battery condition exists in the systems battery.
UL: Required for UL commercial burglar alarm installations and
required for residential fire alarm installations.
*64
Test Report Code
0 = no report
1-F = see description above *59
NOTE:
Make sure the Real-Time Clock
is set to the proper time
before
entering
the test report schedule command to
ensure that test reports are sent when
expected. (see Setting the Real-Time
Clock section on page 12-3)
Sent periodically to test that the communicator and phone lines are
operational.
Frequency of report is set in Scheduling mode
(event 11) or by the following key commands:
installer code + [#] + 0 + 0
= test report sent every 24 hrs
installer code + [#] + 0 + 1
= test report sent once per week
installer code + [#] + 0 + 2
= test report sent every 28 days
Each of these modes sets schedule 32 (VISTA-20P) or 8
(VISTA-15P) to the stated repeat option; first test report sent
12 hours after command
.
UL: Required for UL commercial burglar alarm installations and
required for residential fire alarm installations.
*65
Open Report Code
0 = no report
1-F = see description above *59
This is sent upon disarming of the system in the selected partitions.
UL: Required for UL commercial burglar alarm installations.
*66
Arm Away/Stay Report Code
0 = no report
1-F = see description above *59
This option allows for independent programming of Away and Stay
reports for each partition, including the common lobby.
NOTE:
OPEN reports are not sent if the associated closing report
is not enabled.
*67
RF Trans. Low Batt. Report Code
0 = no report
1-F = see description above *59
Sent when a wireless transmitter low-battery condition exists.
UL installations: must be enabled if wireless devices are used.
*68
Cancel Report Code
0 = no report
1-F = see description above *59
This is sent upon disarming of the system after an alarm condition
was reported.
*70
Alarm Restore Report Code
0 = no report
1-F = see description above *59
Sent when an alarm zone is restored to its non-faulted condition.
UL: Required for UL commercial burglar alarm installations and
required for residential fire alarm installations.
*71
Trouble Restore Report Code
0 = no report
1-F = see description above *59
This is sent when a trouble in a zone is restored
UL: Required for UL commercial burglar alarm installations.
4-5
Vista de pagina 30