Keypads
Keypads are identified by predefined addresses (starting at address 16) as follows:
Address Keypad Program Field
16 keypad 1*
•
always enabled for partition 1, all sounds enabled.
NOTE: First keypad is address 16.
17 keypad 2
•
data field *190
18 keypad 3
•
data field *191
19 keypad 4
•
data field *192
20 keypad 5
•
data field *193
21 keypad 6
•
data field *194
22 keypad 7
•
data field *195
23 keypad 8
•
data field *196
To enable keypads:
1. Set desired address at keypad (refer to keypad’s instructions for setting the address).
2. Use data field program mode to enable keypad addresses, assign a partition, enable sound options
in fields *190-*196 as shown in the table above.
3. If desired, use data field *198 to turn on the display of the partition number.
4. Set the following keypad-related data fields as required by the installation:
*21 Quick Arm Enable
*23 Forced Bypass
*84 Auto STAY Arm
Wireless Receiver and Transmitters
If using a wireless receiver, set the receiver’s address to “00” using its DIP switches, then program
the following options:
*22 RF Jam Option
†
*24 RF House ID Code (if using wireless keypads) for each partition
*67 Transmitter Low Battery Report Code
†
*75 Transmitter Low battery restore report code
†
Use *56 Menu mode to program wireless zones (VISTA-20P: zones 9-48, buttons 49-64; VISTA-15P: zones 9-34, buttons 49-56).
†
These fields must be enabled for Residential Fire and UL Residential Burglar Alarm, and UL Commercial Burglar Alarm
installations.
Pager Programming
The system can send various reports to several pagers (VISTA-20P = up to 4; VISTA-15P = up to 2).
To program pager reporting, do the following:
1. Enter the appropriate information in the following data fields:
*160, *163, *166, *169 Pager Phone Numbers (for pagers 1-4
†
respectively)
*161, *164, *167, *170 Pager Prefix Characters (for pagers 1-4
†
respectively)
*162, *165, *168, *171 Pager Reporting Options by Partition
†
(for pagers 1-4 respectively)
2. Enable Pager Delay, if desired, in field *172 (delays alarm reporting for ALL pagers).
3. Enable appropriate user open/close pager reports using the user attribute command
(master code + [8] + user no. + [#] [5] + [1]). Users that perform actions in partition 1 will, if
enabled, attempt to report to all pagers enabled for open/close reporting in partition 1. Users that
perform actions in partition 2 will, if enabled, attempt to report to all pagers enabled for
open/close reporting in partition 2.
4. If using latchkey pager report, define the latchkey report schedule using Scheduling mode (master
code + [#] [6] [4] then select event type “03”).
5. If using a function key to manually send a message to a pager, see Function Keys paragraph on
the next page.
6. If reporting zone alarms and troubles to a pager, use *81 Zone List menu mode to assign the zones
associated with each pager (zone lists 9-12
†
).
† VISTA-20P supports four pagers and partitioning; VISTA-15P supports two pagers and zone lists 9
and 10 only.