66
Appendix D: Programming Summary
PROGRAMMING FORM
V1.46 PANELS
THE DEFAULT VALUES FOR EACH OPTION ARE SHOWN IN BRACKETS
DEFAULT MASTER CODE 1234 (User 1)
DEFAULT ENGINEER CODE 9090 (User 0)
To enter programme mode, enter your Engineer Code then #, then
*
(Power LED will flash, Spanner Flashes, Displays 00).
To exit programme mode press #, then
*
(Power LED on steady, Spanner/00 clears).
To programme each option, you must enter a Group N˚ then the option/zone N˚, then your selection, i.e., to programme zone 6 to be a
panic zone in the full set mode, enter 167. To put zone 3 on soak test, enter #231.
To view the programme in groups 1, 2, #2, 3, 4, 5, #6, 7 & 9, enter the Group N˚ followed by 00. Each group option will display in turn.
To view groups #1, 6, 8 & 0 enter Group N˚ followed by 0 then the N˚ of the option you want to view. The individual option will display.
ZONE PROGRAMMING
FOR FULL SET
GROUP ZONE ZONETYPE
1 1 (1)
1 2 (4)
1 3 (3)
1 4 (3)
1 5 (3)
1 6 (3)
1 7 (3)
1 8 (3)
ZONE PROGRAMMING
FOR NIGHT SET
GROUP ZONE ZONE TYPE
3 1 (1)
3 2 (1)
3 3 (3)
3 4 (3)
3 5 (3)
3 6 (3)
3 7 (3)
3 8 (3)
ZONE PROGRAMMING
FOR PART SET
GROUP ZONE ZONETYPE
2 1 (1)
2 2 (4)
2 3 (3)
2 4 (3)
2 5 (3)
2 6 (3)
2 7 (3)
2 8 (3)
ZONE TYPES
0 = NOT USED
1 = FINAL EXIT
2 = KEYSWITCH
3 = ALARM
4 = INTERMEDIATE EXIT
5 = TAMPER
6 = SILENT PA
7 = AUDIBLE PA
8 = EXIT TERMINATOR
9 = FIRE
GROUP
OPTION SELECTION
4 1=EXIT TIME (0=FINAL CONTACT/1-9 EXIT TIME X 10 SEC) (3)
4 2=ENTRY TIME (1-9 ENTR
Y TIME X 10 SEC) (3)
4 3=BELL CUT OFF TIME (SEE TABLE 1) (8)
4 4=PART SET EXIT W
ARNING (0=SILENT, 1=KEYPAD ONLY, 2=KEYPAD & SOUNDER) (0)
4 5=EXTERNAL BELLS & STROBE IN PART SET (0=NO, 1=YES) (1)
4 6=EXTERNAL BELLS & STROBE IN NIGHT SET (0=NO, 1=YES) (1)
4 7=TRIGGER OUTPUT
(SEE TABLE 2) (0)
4 8=EASY SET (#) (0=NO, 1=YES) (0)
4 9=PREVENT SET WITH FOLLOWING CONDITIONS (SEE T
ABLE 3) (0)
Table 1
BELL CUT OFF TIMES
0 = CONTINUOUS BELLS
1 = 1 MINUTE
2 = 2 MINUTES
3 = 3 MINUTES
4 = 4 MINUTES
5 = 5 MINUTES
6 = 10 MINUTES
7 = 15 MINUTES
8 = 20 MINUTES
9 = 30 MINUTES
Table 3
T
able 2
TRIGGER OUTPUT
0 = SET
1 = 0V DETECTOR RESET
2 = SET LATCH POSITIVE
3 = ALARM
PREVENT SET WITH FOLLOWING
CONDITIONS
0 = MAINS FAIL
1 = LOW BATTERY
2 = MAINS FAIL AND LOW
BATTERY
SYSTEM OPTIONS
GROUP OPTION SELECTION
5 1=AUDIBLE WARNING OF AC LOSS (0=NO, 1=YES) (0)
5 2=SUPPLEMENTAR
Y ENTRY (0=NO, 1=YES) (0)
5 3=ENGINEER RESET FOR ALARMS (SEE TABLE 4) (0)
5 4=HOTKEY ENABLE (0=NO, 1=YES) (0)
5 5=KEYPAD TAMPER LOCKOUT (0=NO, 1=YES) (0)
5 6=BELL OUTPUT (0 = NEG APPLIED, 1=NEG REMOVED) (0)
5
7=ALARM TRIGGER OUTPUT (0 = NEG APPLIED, 1 NEG REMOVED) (0)
5 8=ENGINEER RESET FOR DAY TAMPERS (SEE TABLE 4) (0)
5 9=ZONE CONFIGURATION (0=N/C LOOP
, 1=DOUBLE BALANCE,
2=E.O.L.) (0)
Table 4
ENGINEER RESET
0 = CUSTOMER
1 = ENGINEER
2 = TECHNISTORE
3 = ENGINEER &
TECHNIST
ORE
GROUP OPTION SELECTION
6 1=PRIMARY TELEPHONE NO. (20 DIGITS) (#=2 SEC PAUSE)
6 2=SECONDAR
Y TELEPHONE NO. (20 DIGITS) (#=2 SEC PAUSE)
6 3=ACCOUNT NO. (4 - 6 DIGITS)
6 4=USER 8 = DURESS CODE (0=NO, 1=YES) (0)
6 5=DOWNLOADER TELEPHONE NO. (20 DIGITS) (#=2 SEC PAUSE)
6 6=DOWNLOADER ID N˚ (8 DIGIT NUMBER, CANNOT BE VIEWED)
6
7=RING COUNT (00=NEVER ANSWER INCOMING CALLS
01-14=NUMBER OF RINGS, 15=ANSWER MACHINE DEFEAT) (14)
6 8=COMMUNICATOR FORMA
T (0=COMMUNICATOR OFF,
1=HIGH SPEED, 2=CONTACT ID) (1)
6 9=C/S RECEIVER HANDSHAKE OPTIONS (0=UK, 1=BELGIUM, 2=PARIS) (0)
RF ZONE PROGRAMMING
OVERRIDES HARDWIRE ZONES
GROUP ZONE SUPERVISION LOOP N˚. 7 DIGIT SERIAL NO.
#1 1
#1 2
#1 3
#1 4
#1 5
#1 6
#1 7
#1 8
ZONE SOAK TEST
ENABLE (14 DAY)
GROUP ZONE 1=ENABLE
#2 1 (0)
#2 2 (0)
#2 3 (0)
#2 4 (0)
#2 5 (0)
#2 6 (0)
#2 7 (0)
#2
8 (0)
RF ZONE. PROGRAMMING
ENTER 9 DIGITS PER ZONE
IN SEQUENCE:
1=SUPERVISION 0=NO, 1=YES
2=LOOP N˚ 1=1, 2=2
3 -9=SERIAL N˚ 7 DIGITS
TO CLEAR RF
ZONE, TYPE 0, 0
FOR SUPERVISION & LOOP
Vista de pagina 73