19
Programming Groups 1, 2 and 3 (Zone Programming For Full,
Part and Night Set)
Programming Groups one to three are used to programme the eight zones for each of
the three setting modes: Full, Part and Night Set. This allows zones to be isolated or
assigned different functions for each of the three setting conditions.
The available zone types are:
0. Not Used 5. 24 hr tamper
1. Final Exit 6. PA silent
2. Key switch 7. PA audible
3. Alarm 8. Push-to-set
4. Walk Through 9. Fire
Zone Programming — Group 1 Full Set
In programming mode:
• The first digit entered is 1 for Full Set.
• The second digit is the zone number 1 — 8.
• The third digit is the zone type, see table 3.2.
Example: In Programming Mode press 1 + 2 + 3. This programmes Zone 2 as an
Alarm in the Full Set mode and is accompanied by two beeps, indicating a
correct entry.
To view the programming: press the 1 key followed by 00. The zone type is indicated
on the keypad zone LEDs (Icon display) for zone 1 (accompanied by one beep), then
zone 2 (accompanied by one beep), etc.
Note: Zone type nine (Fire) is represented by the Tamper LED (9) and zone type
zero (Not used) is indicated by the Day LED (•).
Zone Programming — Group 2 Part Set
In programming mode:
• The first digit entered is 2 for Part Set.
• The second digit is the zone number 1 — 8.
• The third digit is the zone type.
teSlluF
puorG
enoZ
oN
enoZtluafeD
epyT
11 )1(
12 )4(
13 )3(
14 )3(
15 )3(
16 )3(
17 )3(
18 )3(
Table 3.2 Full Set Zones
teStraP
puorG
enoZ
oN
enoZtluafeD
epyT
21 )1(
22 )4(
23 )3(
24 )3(
25 )3(
26 )3(
27 )3(
28 )3(
Table 3.3 Part Set Zones