47
5 — 24 Hour Tamper
A 24 Hour Tamper zone is used for system tampers and for zones covering sensitive
areas such as stock rooms, fire doors, external bell box, etc.
If a 24 Hour Tamper zone is activated when the system is Unset, the keypads sound
and the corresponding zone LED (No.) on the keypad illuminates. External sounders
do not operate.
It is strongly recommended that a zone programmed as 24 Hour Tamper is pro-
grammed in one of the following ways:
• Programmed as 24 Hour Tamper in Groups 1 (Full Set), 2 (Part Set) and 3 (Night
Set).
• Programmed as 24 Hour Tamper in Group 1 (Full Set), and, 0 (Not Used) or 24
Hour Tamper in Groups 2 (Part Set) and 3 (Night Set).
Programming a zone in Group 1 (Full Set) also covers the unset condition.
6 — PA Silent
The PA Silent zone type is assigned to a panic button. Activation of a PA Silent zone
does not cause any audible indication and no indication is given on the keypad display
until a valid code is entered at the keypad. The activation is reported via the Accord
xpC dialler.
It is strongly recommended that a zone programmed as PA Silent is programmed in
one of the following ways:
• Programmed as PA Silent in Group 1 (Full Set), 2 (Part Set) and 3 (Night Set).
• Programmed as PA Silent in Group 1 (Full Set), and, 0 (Not Used) or PA Silent
in Groups 2 (Part Set) and 3 (Night Set).
Programming a zone in Group 1 (Full Set) also covers the unset condition.
7 — PA Audible
A PA Audible zone is assigned to a panic button. Activation of a PA Audible zone
initiates a full alarm condition. The activation is also reported via the Accord xpC
downloader.
It is strongly recommended that a zone programmed as PA Audible is programmed in
one of the following ways:
• Programmed as PA Audible in Groups 1 (Full Set), 2 (Part Set) and 3 (Night
Set).
• Programmed as PA Audible in Group 1 (Full Set), and, 0 (Not Used) or PA
Audible in Groups 2 (Part Set) and 3 (Night Set).
Programming a zone in Group 1 (Full Set) also covers the unset condition.