Set-up
Both the 6128RFH and 5882H need to have the addresses set before use with the
Accord panel. The receiver must always be set to address 0.
6128RFH Keypad
There are two addresses to be set on this keypad as follows:
Keypad address (cA) needs to be 01.
Receiver address (rA) needs to be 00.
To set these addresses:
1. Either repower the keypad or activate the keypad tamper switch.
2. Within 30 seconds of step 1, press and hold buttons 1 and 3 for five seconds.
3. The display will alternate between 00 and — (program mode).
4. Press 1 and display will show cA (keypad address).
5. Type 01 then press Ö. Display will return to 01 and —.
6. Press 2 and display will show rA (receiver address).
7. Type 00 then press Ö. Display will return to 00 and —.
8. To finish the programming procedure, press Ö once more and the keypad is ready
for use with the Accord xpC panel.
5882H Receiver
Set all the dip switches to OFF before powering up the unit. This addresses the unit as
0. No other settings are required on this unit.
Wire Free Programming
Programming wire free zones
From programming mode:
1. Ensure that a receiver is connected and set up as detailed previously.
2. Program the zone numbers as for hard wire zones in program groups 1, 2 and3.
3. For each detector in turn, go to program group #1 and enter the following
information:
Zone Number (1 digit, 1 - 8)
Supervision (1 digit, 0 = not supervised, 1= supervised. PIRs, door
contact and smoke detectors are, panic buttons are not)
Loop number (1 digit, 1=loop 1, 2=loop 2. Most devices are loop 1Ö)
Serial number (7 digits, Enter the 7 digit serial number on the sticker on
the detector)