ADEMCO Accord Manual de instalación Pagina 68

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 78
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 67
60
Programming the Time and Date
The time and date may be set through the keypad by entering any valid code and
pressing # 0 (Log) then DDMMYYHHMM where DD is the day of the month (01 –
31), MM is the month (01–12), YY is the year (00 – 99), HH is the hour (00 – 23) and
MM is the minute (00 – 59). Confirmation beeps acknowledge that a valid date and
time have been entered. The time and date can also be set using the Ademco
Microtech Downloader software, for more information see the Accord xpC
Downloader Instruction Manual.
Note: Time defaults back to 00:00 1/1/00 when the power is switched off.
Hot Keys
When Hotkey function is enabled (Group 5 – Option 4), Assistance, Fire and Panic
alarms will function via a double push on the keypad (see table below).
yeKtoHepyTNdapyeK
0
DCL
yalpsiD
1 ecnatsissA6+4
2 eriF9+7
3 cinaP
Ö #+
Note: Hotkey buttons must be pressed for 2 seconds for hotkey function.