33
Group #6 - Option 3 Walk Through Affects Confirm
This selects if a walk through type zones will contribute to confirmed alarms. This
option has two settings:
0 Not After Timeout
This setting means that if a walk through zone is activated during the set period before
an entry door has been opened, it will contribute towards a confirmed alarm. If it is
activated after an entry zone has been opened, even after the timeout, they will not
contribute to a confirmed alarm.
1 Whenever Activated
This setting means that a walk through zones will contribute to a confirmed alarm
whenever it is activated in the set condition, except when the entry timer is running.
Group #6 - Option 4 Full Reset for Unconfirmed Alarms
This option selects whether a full system reset is required for an unconfirmed alarm. If
enabled (1), then a reset as dictated in Group 5, Option 8 will be required for all
alarms. If disabled (0), then the entry of a user code to unset the system following an
unconfirmed alarm, will also reset the system.
Group #6 - Option 5 Signal Locked out zones
This option dictates at what point the re-arm occurs when activated zones are being
omitted and signalled to the monitoring station. There are two settings:
0 On Confirm Timeout
Omitted zones will send an omit signal at the end of the confirm time window.
1 On Bell Timeout
Omitted zones will send an omit signal at the end of the bell time.
Group #6 - Option 6 Entry Timer Clears Confirm Count
This options selects whether a single (unconfirmed) alarm activation is remembered
for the purposes of confirmation, after an entry door is open. This option has two
settings:
0 Resets Count
In this case, the confirmed alarm counter is reset to 0 as soon as an entry door is
opened.
1 Keep Count
In this case, the confirmed alarm counter is maintained. If there is one alarm activation
before the entry door is opened, and then another activation after the entry delay
expires, a confirmed alarm condition will be generated, provided that both activations
occur within the confirm time window.