Set to 2 (Technistore): User code can cancel a day tamper activation but a Technistore
reset number must be entered to reset the system.
Set to 3 (Engineer or Technistore): User code can cancel a day tamper activation but
either the engineer code or a Technistore reset number must be entered to reset the
system.
This option defaults to 0 (customer).
Note: This option only affects Tamper conditions occurring when the system is
unset. It does not affect tamper conditions occurring when the system is in one
of the set modes; these tamper conditions are covered by menu option Group 5
– Option 3 Engineer Reset for Alarms.
Group 5 - Option 9 Zone Configuration
The zones on the Accord xpC function as Normally Closed, Double Balanced, U.S.
End of Line.
0. Normally Closed
1. Double Balanced
2. U.S. End of Line
This option defaults to (0) Normally Closed.