SPECIFICATIONS
4140XM CONTROL
Physical:
Width:
12 inches (305mm)
Height:
12 inches (305mm)
Depth:
3 inches (76mm)
Electrical:
VOLTAGE INPUT: 18VDC, 85o mA max. (from plug
in Power Pack, Ademco No. 136o)
RECHARGEABLEBACK-UPBATTERY:12VDC, 4 AH
(Gel type)
A!ARM SOUNDER OiJTPi.JT:Wet contactrelay (2.8A
max. contact rating @ 28VDC). Can drive 12V
motor driven blla (100 mA each) - AMSECO
MSB1OG or ABB1031.
AUXILIARY POWER OUTPUT: 11,5- 14.OVDC
700 mA for non-UL installations
400 mA max. for UL installations
STANDBY. 5.7 hours with Auxiliary load of 700
mA using 4 AH Battery. 8.5 hours with Auxiliary
load of 400 mA using 4 AH Battery
Fuses:
Battery Fuse: 3A Slo Blo (Ademco No. 90-28)
Auxiliary Powec 1A (Ademco No. 90-29)
Alarm Relay Powrm 3A Sio Bio (Ademco No. 90-28)
DIGITAL COMMUNICATION INTERFACE
BOARD (4171 XT-XM)
Phyelcal: 5-3/4” (14.6 cm) x 3-1/8= (8.25 cm)
x 7/8. (2.2 cm) (approx.).
Functional:
FORMATSSUPPORTED
ADEMCO LOW SPEED, 10 pUk3/sOC. 1900 HZ
Data Tone, 1400 Hz ACiVKISSOFF.
SESCO/$ 20 puhee/eec, 1800 Hz Data Tone,
2300 Hz ACWKISSOFF, Variable Interdigit
Timing.
RADIONICS, 20 puieeamec, 1800 Hz Data
Tone, 2300 Hz ACWKISSOFF, Fixed Interdigit
Timing.
ADEhCO CONTACTID
LINE SEi2f2 DoublePole
RINGER EQfJfVALENCE0.7S
FCC REGISTRATION NO.: AC 3g8U-66192-AL-E.
5130xM/4130xM
Physical: Width:
Height:
Depth:
Electrical:
CONTROLS
8.4 inches (21.3cm)
4.75 inches (12.1 cm)
1.1 inches (2.8 cm)
VOLTAGE INPUT: 18VDC (from plug-inPower Pack,
Ademco No. 1350), 700 mA max.
RECHARGEABLEBACK-UPBATTERY 12VDC, 1.2 AH,
Ademco No. 484 (YUASA NP 1212). (Alternatively, a
4 AH Ademco No. 486 may be used”).
ALARM SOUNDER: Built-inpiezoeiectnc sounder,
85 db at 10 feet. Sound producedis selectableas
‘steady” (in
compliance with UL 85 db output
requirement) or ‘sweeping” (for non-UL usage).
Optional external 12V Piezoelectric alarm sounder
(100 mA max.). (Ademco No. 740 or BRK PA400B).
Optional 12V motor-driven Bell (100 ma max.).
(AMSECO MSB1O-G or ABB-1031).
Optional dry contact relay (2.8A max. contact rating
@26VDC). Ademco No. 4148°. Can drive No. 719 or No.
702 Siren.
AUXILiARY POWER OUTP~ 1O.2-13.8VDC
280 mA for non-UL installations
200 mA max. for UL installations
STANDBY: 2.5 Hours with 200 mA standby currant
load. 5 Hours with no external currant load.
‘Not available in a UL installation.
5137/4137
REMOTE CONSOLES
Ph ysicel: Width: 8.4 inches (213 mm)
Height: 4.75 inches (121 mm)
Depth: 1.1 inches (28 mm)
Eiectricai:
Voltage Input 12VDC
Current Drain:
80 mA (4137) continuous
90 mA (5137) with back iighting
interface Wiring:
RED: 12VDC input (+) - auxiii~ power
BLUE: 18VDC input (+) - from optional 1350 or
1360 Power Pack*
GREEN: Datain
YELLOW: DataOut
BLACK Groundand (-) connectionfrom
optional 1350 or 1360 Power Pack.
● Not permitted for UL installations.
1
TO THE INSTALLER
I
Reguiar maintenance and inspection (at least annuaiiy) by the instaiier and frequent testing by the user are vital
to continuous satisfactory operation of any aiarm system.
The instaiier shouid assume the responsib~ of developing and offering a reguiar maintenance program to the
user as well as acquainting the user with the proper operation
and imitations of the alarm system and its
component parts. Recommendations must be inciuded for a specific program of frequent testing (at
least
weekiy) to insure the system’s proper operation at all times.
-17-