V. SYSTEM OPERATION
SECURITY ACCESS CODES
The VISTA XM System allows up to 22 security
The Installer also programs the master security
access codes
to be assigned, each identified by a code, which is the code intended for use by the
user ID numkr.
primary user of the system. The master code can
The installer programs an Installer’s Code initially
then be
used to assign up to twenty temporary
as part of the programming procedure, and this
codes, which can be used by secondary users of the
code is the only code that permits re-entry into the
system who do not have a need to know the master
programming mode (unless 98 has been previously
code. In addition,the Quick Arm feature can also be
used to exit the programming mode, see below).
programmed, which enables the [#] key to be
The Installers Code can also be used to perform
pressed in lieu of entering the security oode when
normal system functions, but cannot assign
arming the system.
temporary cod6s.
As shipped from the factory, an initial Installer’s
The system also provides an Installer Code lock-out
coda and master code is pm-programmed, and can
feature, which prevents the use of the Installer’s
be changed by the installer to any code desired.
Code from re-accessing the Programming mode
The pre-programrned codes are as follows:
after the initial programming.
This feature is
activated by pressing 98 to exit Programming
4130XM = 4-1-3-0 All Controls = 1-2-3-4
mode. The only way to access Programming mode
once this feature is activated, is by powering don
4140XM = 4-1-4-0
the system and powering up again, and then
5130XM = 5-1-3-O
pressing both the
and # keys at- the same time
within 30 seconds of power up. If re-acceas to
For additional information about security codes,
Programming mode using the Installer’s Code is
refer to the
Technics/ Reterence Manual and/or the
desired after initial programming, then exit
User’s Manual.
Programming mode by pressing “99.
RECALLING ALARM & TROUBLE MESSAGES
The system’s alarm memory retains all eventa for
a period of 10 days, starting at the time of the
firat event. Upon expiration of the 1O-day period,
all history is automatically erased and the alarm
memory will reset. The next 10-day cycle will
begin when the next event occurs.
Recall by service personnel will display all events
that have occurred from the start of the 10-day
cycle to the time of recall. Note that Recall will end
any 10day cycte in progress. The LCD display on
the 4130XM/41 37 console will indicate the number
of the zone in which the event occurr”ed(e.g., 01,
02, etc.), accompanied by the word CHECK
(trouble), ALARM and, If applicable, FIRE, to
describe the type of event that occurred in the
displayed zone.
KEYPAD
The keypad atlows the user to arm and disarm the
system, and perform other system functions, such
as bypassing zones, view messages from the
central station and display zone descriptors. Zone
and system conditions (alarm, trouble, bypass) are
displayed in the Display Wtndow.
If a 5130XfvV5137 is used, an alpha descriptor of
the zone will be displayed in addition to its zone
number. If more than one event had occurred, the
events will be displayed in numerical sequence.
Each disptay will appear for 1-2 seconds, then the
next event will be displayed. When all eventa have
been displayed, the displays are repeated.
To display
the 10-dey hletory, enter the
security code and press the O key.
To xit Recsll, enter the security code and
press the OFF key. All existing memory is erased
and the alarm memory is reset. The 10-day cycle
will start again only when the next event occurs.
FUNCTIONS
For additional information, refer to the User’s
Manual.