PASSIVE INFRARED MOTION DETECTORS
GENERAL INFORMATION
POLLING LOOP PIR (4196)
Select a mounting site with the following notes in
The 4196 is a quad element passive infrared
mind: Best coverage will be obtained if the
detector with a built-in RPM that is connected
mounting site is selected such that the likely
directly to the 2-wire polling loop.
direction of intruder motion is across the pattern of
POLLING LOOP PIR (4275)
protection.
The 4275 is a dual element passive infrared
Avoid locating the unit where central heating
detector, with a built-in RPM, that is connected
radiators, flames or heating outlet ducts are
directly to the 2-wire polling loop.
within the protective zones.
WIRELESS PIR (5775)
Avoid locating the unit in direct sunlight or
The 5775 is a battery operated, wireless, dual
directly above strong sources of heat.
element passive infrared motion detector that can
Avoid locating the unit on unstable surfaces.
be monitored by a 4280 (4280-8) wireless
Avoid running alarm wiring close to heavy duty
receiver. The 4280 is connected to the 2-wire
electrical cables.
polfingloop.
PHONE LINE INTERFACE
4171 XT-XM/4171XM INSTALLATION 4171 XT-XM/4171XM TERMINALS
The 4171 XT.XM is factory installed in the 4140XM Term. 1: Programmable output (see 1
46) that can
Control.
For the 4130XM/51 30XM Controls,
be used as a ground start output with the 675
connect the 4171 ~-XM or 4171 XM as shown:
Ground Start Module (not UL Listed), as an outputto
produce console audible warnings on a remote
sounder (ex: No. 706-12), or as an open/close
trigger for use with other communicationsmedia.
ST-S u,
Q Only one of the above optionscan be chosen.
o
un9*8-
-- m-)
mac4muac,
A
HUIDaas
.
If either GROUND START, or CONSOLE AUDIBLE is
w_—s
used, Aux. Voltage Trigger pin 4 may not be used.
c
o
0
@~
8
Term. 2: INCOMING PHONE UNE (TfP)
h
~,,~e,.,,~ Term.3: INCOMINGPHONE UNE (RING)
*TC-ACE
ammo
Term. 4: LOCAL HANDSETS (RING)
Term. 5: LOCAL HANDSETS (TIP)
c
o
;::;? ~&#”
-c -S*
GROUND: Connect green flying lead to a proper
—nal —nm
N?ww yml?a-
9
mm
earth ground.
*- -Au
moon o-tn
~=mmmoem
WARNING:
To prevent the risk of shock,
disconnect phone lines at telco jack before
.,
servicing the unit.
EXTERNAL SOUNDERS
4140XM
4148 RELAY MODULE (2.8 AMPS @28 VDC)
The 4140XM is housed in a metal cabinet and
Other sounders (ex. 702 and 719 self-contained
contains a built-in relay, rated at 2.8 amps. The
sirens) can be used with the 4130XM/5130XM, but
output of this relay is a positive (+) trigger from
the addilion of the 4148 Relay Module is necessary
terminal 8 on TB2, with the negative from TB2-15.
because these sirens (or equivalent) draw more
Up to two 702s can be used wired in series; up to
than the allowable 100mA of current.
two 719s in parallel.
ADVISORY:
4130x M/5130x M
Going beyond the above mentioned limits will
The 4130XM/51 30XM self-contained Controls have
overload the auxiliary power and/or relay fuse.
an external sounder output of 100mA, (negative-
Note that the 5130XM and 4130XM use built-in
going (-) trigger) from the brown lead. The
eolid state fuses (PTCS) that do not need replacing.
continuous. positive (+) is taken from the red/black
The 4140XM
uses standard fuses (located on the
lead. From this output you could use up to two 740
terminal strip) which must be replaced if blown.
High Intensity Sounders, wired in parallel, or one
Arnseco Motor Bell, ABB1031, or
Piezo Sounders, BRK PA400B in
up to eight indoor
parallel.
-9-