PROMPT
EXPLANATION
02 RELAY GROUP
00
Relays may be grouped for common activation by time-driven events (commands 06-10). Enter 00 (no
group) or 01-15 for a specific group number.
Press [] to continue.
02 RESTRICTION
1=YES 0=NO 0
The system may have some devices that are not intended to be under end user control, such as relays
activating fire doors or machinery. Enter 1 if the end user will be restricted from accessing this relay group.
Press [] to continue.
02 RELAY TYPE
V-PLEX 0
Enter 0 for V-Plex (polling loop) devices. Enter 1 for (ECP) relay modules (4204/4204CF). Enter 2 for X10
devices. Enter 3 for (FSA) Fire System Annunciator.
Press [] to continue.
02 V-PLEX ZONE #
000
For polling loop trigger outputs (4101SN), enter the protection zone number (001-250) linked to each output,
if used. Be sure to enroll the modules serial number (see Zone Programming).
Press [] to continue.
02 ECP ADDRESS
00
If you selected 1 or 3 for (4204/4204CF or FSA), enter the actual module's address (01-15 4204/4204CF)
(08-23 FSA) as set by its DIP switches. Up to 8 4204/4204CF modules and up to 4 FSA modules can be
installed in a system.
Press [] to continue.
02 MODULE RELAY#
0
For 4204 Relay Outputs, enter the specific relay number on that module (1-4). For 4204CF outputs,
enter
only module relay number 1 (Output A) or relay number 3 (Output B)
. These are the only two
programmable relays on the 4204CF Module.
Press [] to continue.
The keypad will display the Start and Stop summary screens again.
Press [] to continue.
02 HOUSE CODE
A 00
If you selected 2 for X-10 devices, enter the numerical equivalent of the House Code of the device, as
follows:
A=00 D=03 G=06 J=09 M=12 P=15
B=01 E=04 H=07 K=10 N=13
C=02 F=05 I=08 L=11 O=14
02 UNIT CODE
00
Enter the numerical unit code of the X-10 device (00-15).
Press [] to continue.
The keypad displays the Start and Stop summary screens again.
Press [] to continue.
01 LED #
00
Enter the LED number on the FSA module (01-08 for FSA-8; 01-24 for FSA-24).
Press [] to continue.
The keypad displays the Start and Stop summary screens again.
Press [] to continue.
When all relays have been programmed, enter 00 at the "ENTER RELAY NO." prompt.
If you are defining a zone list, continue to the next section. If not, enter 00 + [] at the next two prompts. You will then be
asked "Quit Menu Mode?" Enter 1 for "Yes," 0 for "No." Then enter 99 to exit programming completely.
If supervision of the 4204CF Relay Output is desired, enter a response type for that output's corresponding supervisory zone.
This is equal to 600 + [Relay ID No.]. For example, if you are programming Relay ID No. 1, the relay's supervisory zone 601.
Program this zone with response type 05 (Day/Night) in
Zone Programming
.
Zone List Programming
After all relays have been programmed, upon entering 00 at the "ENTER RELAY NO." prompt, you are asked to enter a zone
list. If a zone list number was used to start or stop a relay, you must define the zones belonging to that list as follows:
PROMPT
EXPLANATION
ENTER Zn LIST ?
00=QUIT 00
Enter the zone list number 01-15. Enter 00 to quit.