ADEMCO Vista-128B PLUS Guia de preparacion Pagina 18

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 72
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 17
– 18 –
PROMPT
EXPLANATION
001 Tamper Option
none 0
If you selected input type 1, 6, 7, or 8, this prompt displays. If the zone has a tamper switch wired in the
loop in addition to a sensor contact, enter the tamper option.
Enter 1 if the tamper switch is normally closed (wired in series) with the EOL resistor.
Enter 2 if the tamper switch is normally open (wired in parallel) with the EOL resistor.
Enter 0 if a tamper switch is not being used in the loop.
NOTE: For zone response types 9 or 16 (Fire), the tamper selection must be “0” none.
010 V-PLEX RELAY?
1 = YES 0 = NO
If you selected input type 6, this prompt displays. Enter 1 if using a 4101SN Relay Module for this zone.
Otherwise enter 0.
Press [] to continue.
010 CONS ECP ADDR
(00-30) 01
If you selected input type 09, this prompt displays. Enter the ECP address of the keypad that is being used
for entry/exit for this access point (00-30).
Press [] to continue.
010 ACS ZONE #
(00-31) 01
If you selected input type 10, this prompt displays. Enter the PassPoint ACS zone ID that this VISTA zone
maps to (00-31).
Press [] to continue.
010 ACCESS POINT
(01-15) 01
If you selected input types 06, or 11 – 13, this prompt displays. Enter the access point (01-15) to be
controlled by the input type.
Note: For input type 06, the selected address must be 00.
Note: If you are using the VistaKey module, the access point must match the address that was set in the
module.
Press [] to continue.
010 INPUT S/N: L
AXXX-XXXX 1
For Serial Number entry and Loop Number entry, do one of the following:
a. Transmit two open and close (or close and open) sequences. For a button-type transmitter, press and
release the button, wait approximately 4 seconds, then press and release the button a second time.
OR
b. Manually enter the 7-digit serial number printed on a label on the transmitter, using the Alpha keypad.
Then press the [] key, the cursor moves to the “L” position. You can edit the loop number, if necessary.
When the loop number is acceptable, press [].
OR
c. Press key [C] to copy the last serial number enrolled (used when programming a transmitter with several
input loops).
Press [] to accept.
010 INPUT S/N: L
A022-4064 1
The cursor will then move to the Loop column (L) with the previously entered/transmitted serial number
displayed.
Enter the loop number (refer to 5800 Series Transmitters Loop Designations below).
To Delete an Existing Serial Number, enter0“ in the loop number field. The serial number will change to
“0”s.
If “0” was entered in error, simply re-enter the loop number or press [#], and the serial number will return to
the display.
Press [] to accept.
010 INPUT S/N: L
A022-4064 1
The system will then check for a duplicate serial/loop number combination.
If a duplicate serial/loop number combination is found, the keypad will emit a single long beep, and display
the serial number along with a “?” for the loop number, allowing you to re-enter the correct loop number.
If the serial/loop number combination is not a duplicate in the system, a display appears showing the serial
number and loop number entry.
Press [] to continue.