– 32 –
Device Programming
This menu is used to program keypads, receivers, and relay modules, etc.
Device Address 00 is always set as an alpha keypad assigned to Partition 1 with no sounder suppression
options, and these settings cannot be changed.
From Data Field Programming mode, press #93 to display "ZONE PROG?" Press [0] repeatedly to display "DEVICE PROG?"
PROMPT
EXPLANATION
DEVICE PROG?
1=YES 0=NO 0
Press [1] to enter
Device Programming
.
DEVICE ADDRESS
01-30, 00=QUIT 01
The device address identifies the device to the control. Enter the 2-digit device address number to match
the device's physical address setting (01-30).
Notes:
• Device Address 01 is defaulted for an AUI (Symphony) with Keypad Global arm/disarm disabled.
• Device Address 04 must be used for the 4285/4286 Voice Module, if one is utilized. If not, it can be
used for another device type.
• Device Address 24 must be used for TeleSmart, if one is utilized. If not, it can be used for another
device type. If using TeleSmart, you must program Device Address 23 as an alpha console. Do not
connect an actual keypad set to address 23 to the control panel. This setup is necessary for
remote access of TeleSmart.
Press [✱] to accept entry.
Select the type of addressable device as follows:
00 = device not used 06 = long range radio
01 = alpha keypad (6139/6160, AUI) 08 = fire display (FSA)
03 = RF receiver (5881) 09 = Vista Gateway Module (VGM)
04 = output relay module (4204) 10 = panel link module
05 = voice (VIP) Module (4285/4286) 11 = Telesmart
DEVICE TYPE
00
Press [✱] to accept entry.
Alpha Keypad
PROMPT
EXPLANATION
01 CONSOLE PART.
1
If you selected device type 01 (alpha keypad), this prompt appears. Enter the addressable device's default
partition number (01 to maximum number of partitions programmed for system in field 2*00). This is the
primary partition for the device. Enter 9 to make this keypad a "Master" keypad for the system.
Press [✱] to accept entry.
01 SOUND OPTION
00
If you entered device type 01 (alpha keypad), this prompt appears. Keypads can be individually
programmed to suppress arm/disarm beeps, entry/exit beeps and chime mode beeps. This helps prevent
unwanted sounds from disturbing users in other areas of the premises.
Enter a number 00-03 for the keypad sounding suppression options desired for the keypad as follows:
00 = no suppression
01 = suppress arm/disarm & entry/exit beeps
02 = suppress chime mode beeps only
03 = suppress arm/disarm, entry/exit and chime mode beeps
Press [✱] to accept entry.
01 KEYPAD GLBL?
0
If you entered device type 01 (alpha keypad), this prompt appears. Each keypad can give users with access
to multiple partitions the ability to arm and disarm those partitions from it. To enable this keypad for global
arming/disarming, enter 1. To prevent the ability to use this keypad for global arming/disarming, enter 0.
Press [✱] to accept entry.