Choices for Start/Stop Zone Types and System Operations:
00 = No Response (Not Used) 23 = No Alarm Response 41 = AC Power Fail
01 = Entry/Exit #1 42 = System Battery Low
02 = Entry/exit #2 43 = Communication failure
03 = Perimeter
27 = Access Point (allows more than one
relay to be controlled by activation if
access point request)
44 = RF Low Battery
04 = Interior Follower 28 = MLB Supervision 45 = Polling Loop Failure
05 = Trouble Day/Alarm Night 29 = Momentary Exit 47 = Console Failure
06 = 24-Hr. Silent 31 = End of Exit Time 51 = RF Receiver Failure
07 = 24-Hr. Audible 32 = Start of Entry Time 52 = Kissoff
08 = 24-Hr. Auxiliary 33 = Any Burglary Alarm 54 = Fire Zone Reset
09 = Fire Alarm or Trouble 34 = Code + [#] + 71 Key Entry 55 = Disarm + 1 Minute
10 = Interior W/Delay 35 = Code + [#] + 72 Key Entry 56 = XX Minutes (enter XX in field 1*74) *
14 = PLM Supervision 36 = At Bell Timeout ** 57 = YY Seconds (enter YY in field 1*75) *
16 = Fire With Verification 37 = 2 Times Bell Timeout ** 58 = Duress
20 = Arming-STAY*** 38 = Chime
21 = Arming-AWAY**** 39 = Fire Alarm
22 = Disarming (Code + Off) 40 = Bypassing
60 = Audio Alarm Verification (must be
selected for both START and STOP
operation)
* Stop condition only
** Or at disarming, whichever occurs earlier
*** The output also activates when the partition is armed in the INSTANT mode
**** The output also activates when the partition is armed in the MAXIMUM mode
If you are using options 56 and/or 57 (usually as the STOP Zone Type), you must program data fields 1*74
and 1*75 for the respective relay timeouts for minutes and seconds.
PROMPT
EXPLANATION
02 START: ACS PT
(00-31) 00
If the start zone type you selected was 27 (access point), this prompt is displayed. Enter the access point
(00-31) that will start the relay action.
Press [] to continue.
02 START: PARTN
ANY PARTITION 0
If the starting event will be limited to occurring on a specific partition, enter the partition number (1-8) in
which the start event will occur. Enter 0 for any partition.
Press [] to continue.
Do not use a zone programmed with an RF Button (Input Type BR) to STOP a relay. The system will not de-
activate the relay.
PROMPT
EXPLANATION
02 STOP: ZN LIST
00
If a zone list is being used to stop this relay action, enter the zone list number, 1-15. The restore of a zone
on the zone list stops the relay. If a zone list is not being used, enter 0.
Press [] to continue.
02 STOP: ZN TYPE
NO RESPONSE 00
If a Zone Type/System Operation is being used to stop the relay action, enter the 2-digit code listed in the
Choices for Start/Stop System Operation chart.
Press [] to continue.
02 STOP: ACS PT
(00-31) 00
If the stop zone type you selected was 27 (access point), this prompt is displayed. Enter the access point
(00-31) which will stop the relay action.
Press [] to continue.
02 STOP: PARTN
ANY PARTITION 0
This is the partition to which the stop condition will be limited. Enter 0 for any partition. Enter 1-8 for specific
partition number.
Press [] to continue.