6139 Deluxe
Addressable
Alpha Console
Mounting The
Consoles
Wiring Consoles
Powering Additional
Consoles
The 6139 Remote Console is keypad addressable (no DIP switches) console,
and features a red “ARMED” LED which lights when the system is armed, and a
green “READY” LED which lights when the system is ready to be armed (no zone
faults present). This console also features display backlighting. The keypad,
which is continuously backlit for ease in use, is located behind a flip-down
decorative door. The keypad also features dedicated panic keys, labeled A, B, &
C (the D key is not used).
Must be set to the non-addressable mode in this
system (Address 31).
The console can be surface mounted directly to a drywall, or to a single or double
gang electrical box. For flush mounting to drywall, use the optional 6139TRK
flush mount kit.
Note that field wiring to the consoles must be completed before the consoles can
be mounted.
The consoles can be either surface mounted or flush mounted (using an
appropriate Trim Ring Kit: 5137TRK or 6139TRK). Refer to the mounting
instructions and template included with the console and/or trim ring kit for specific
information.
Be sure to take the height of the users into account when mounting consoles.
If convenient, consoles should be wired on individual wire runs to the control. For
maximum wire lengths when using individual wire runs or multiple units wired on
a single run to the control, refer to Table 2 in the section on page 28 entitled
WIRING INFORMATION FOR CONSOLES, RF RECEIVERS, AND OTHER
DEVICES .
As indicated previously, all consoles can be powered from the auxiliary power
output provided that the 700mA rating is not exceeded for all devices drawing
power from the auxiliary output. The backup battery will supply power to these
consoles in the event that AC power is lost.
If necessary, additional consoles can be connected to the system by using a
regulated,
12VDC power supply (e.g., 487-12 supplies 12V, 250mA; 488-12
supplies 12V,
500mA). Use a UL Listed, battery-backed supply for UL
installations.
Connect the additional consoles as shown at left, using the console wire colors
shown. Be sure to observe the current ratings for the power supply used.
IMPORTANT: Make connections directly to the screw terminals as shown. Make
no connection to the console blue wire.
The 487-12/488-12 power supplies have a backup battery which can power these
consoles in the event of AC power loss. Note that consoles powered from
supplies which do not have a backup battery
will not function when AC power is
lost. In this case, be sure to power at least one console from the Control’s
auxiliary power output. “