An optional closed-circuit tamper switch (model 112) can be wired in series
with zone 7, so that,
if the switchplate is removed from the wall, the tamper
will open, disabling keyswitch operation until the system is next disarmed
from the console.
Note: Only one keyswitch with LEDs can be supported by the system’s power
supply.
LED
indications are defined as follows:
GREEN
RED
MEANING
OFF
OFF
DISARMED& NOTREADY
ON OFF
DISARMED& READY
OFF
ON STEADY
ARMEDAWAY
OFF
SLOWFLASH
ARMEDSTAY
OFF
RAPID
FLASH
ALARM MEMORY
1
2345678
I!
a
:
ii
SA4120XM-2
5
5
$
CABLE
KEYSWITCH PROGRAMMING NOTES:
If a keyswitch is used, note the following:
c Program field 15 must be set to “1” to enable the
keyswitch option.
A 2000 ohm EOL resistor must be connected across
the momentary switch, and zones 2-8 must be
programmed for EOLR supervision (“0) in field 41.
For keyswitch operation, Field 157 (Trigger Mode)
must be set for either ‘O” or” 1”.
fARMEO)
*V
r
----- ----
RED
GREEN
I
!?H?$
!
Smn am
—..—----
TAMPER
‘c
.——
e“”
--------t
I
$
!‘—-
~
c%% Eou
L
----------
414SKLWSWITCN
(NOTUL USTED)
NOTE
THE LOCK SWITCH SHOWN
ABOVE (PART OF 4146) IS A
NORMALLYOPEN, MOMENTARY
(SPRING-LOADED)SWITCH.
Figure 3. REMOTE KEYSWITCH WIRING
-21-