– 35 –
Registering the Communication Device with AlarmNet
The communication device must be registered with AlarmNet before internet communication (via IP or GSM) can occur.
Register Using the Alpha Keypad and ∗
∗∗
∗29 Menu Mode
1. Enter *29 Menu mode, select Diagnostic mode, then press Shift then [↑] key (D key followed by the B key). The
registration message is sent (“Registering” displayed) and the control waits for the acknowledgment.
2. “Registration SUCCESS” displayed, indicating successful registration.
Or Register with AlarmNet Direct Website or by Phone
To register via AlarmNet Direct Website, please go to: https://services.alarmnet.com/AlarmNetDirect/userlogin.aspx
.
To register by phone, call 1-800-222-6525. You will need the MAC ID and MAC CRC number and Subscriber information.
Communication Device Status Report Codes
The Communication Device sends status messages to the control panel for network connectivity failures. Trouble messages
are displayed on the keypad as “Check 103,” with status displayed as “LngRng Radio” followed by a 4-digit keypad display
status code, defined below.
Keypad Display Status Codes
CODE DESCRIPTION
0000 Control panel lost communication with internal device
0005 Communication device has lost contact with AlarmNet-G network
000F Communication device is not registered; account not activated
0019 GSM module shut down
0400 Communication device Power-on reset
UPLOADING/DOWNLOADING VIA the INTERNET
UL: Up/downloading via the Internet has not been evaluated by UL.
This control, when used with a compatible Internet/Intranet Communication Device, supports upload/download programming
capability via the Internet using the AlarmNet network or, depending on the communication module used, a Private local area
network (Intranet). This allows site maintenance independent of central station monitoring, and modification to sites globally
via the Internet. Depending on the module used, Internet connection from the protected premises is either via high speed
(broadband) cable or phone service, or via the GSM/GPRS digital cellular network (GSM modules).
Refer to the instructions provided with the communication module for information regarding its installation, programming, and
registration. The System Requirements table below lists two sets of system requirements, depending upon whether you
intend to communicate over the Internet or whether you are communicating over a Private LAN (Intranet).
Compatible Communication Modules: The following modules support Internet uploading/downloading, but future modules
may also provide Internet upload/download support; refer to the module’s instructions for compatibility. Compatible Modules:
7845i-ent (supports LAN), GSMV4G, GSMX4G, IGSMV4G
System Requirements
Internet Communication
At the Installation Site:
• Appropriate Internet Communication Module
• 7720P Programmer
• Broadband Internet Access (for wired modules)
• Broadband (Cable/DSL) Modem (for wired modules)
• Broadband (Cable/DSL) Router (for wired modules if
connecting more than one device to the Internet)
• IP compatible Control Panel
At the Downloading Office:
• Broadband Internet Access
• Broadband (Cable/DSL) Modem
• Broadband (Cable/DSL) Router (optional, if connecting
more than one device to the Internet)
• Computer running Compass Downloading Software
version that supports Internet upload/download for this
control.
Intranet (Private LAN) Communication, if applicable*
At the Installation Site:
• Internet/Intranet Communication Module
• 7720P Programmer
• Ethernet Network Connection
• IP compatible Control Panel
At the Downloading Office:
• 7810iR-ent IP Receiver and Internal Router
• Computer(s) running the following software:
- Compass Downloading Software version that supports IP
upload/download for this control.
- Compass Connect Data Server Application
- Compass Connect Control Server Application
* see module’s instructions for applicability for LAN usage
NOTE: Compass, the Compass Connect Data Server, and the
Compass Connect Control Server applications may all be installed
on the same computer if desired. If they are installed on one
computer, the computer must have a fixed IP Address.
To set up the control panel, do the following:
1. Connect the communication device to the control panel’s ECP (keypad) terminals.
2. Internet Users: Connect the communication device to the Internet via a cable/DSL modem and router.
Intranet Users: Connect the communication device to the Intranet (LAN) via the appropriate Ethernet connection.
3. Enable the communication device (using ∗29 Menu mode) to enable alarm reporting and module supervision.
4. Using the communication device’s programming menus (via ∗29 Menu mode or 7720P programmer), program the
communication device for address 3 and program the device’s other options as required.
5. Register the communication device with AlarmNet. The communication device must be registered before downloading or
alarm reporting can take place.
To perform upload/download functions:
1. Connect the computer to the Internet and start the Compass downloading software.
2. Open the control’s account, then select the Communications function and click the Connect button.
3. At the Connect screen, check that the control’s MAC address is entered and the TCP/IP checkbox is checked.
4. Click Connect. The Internet connection to the control is made automatically via AlarmNet.
5. Once connected, use the Compass downloading software as normal to perform upload/download functions.